Poznámky redaktora
cores x
cross-sec.Tauchflex-R750 blue, submersible-pump cable
Properties
Cable structure
Technical data
Ⴠ Bare copper-conductor, to
DIN VDE 0295 cl.
kg km
Cop. +40°C, max.cores x
cross-sec.
16
54,0
14,0
6,0
1 1,5
37100 8
750,0
288,0
19,0
3 10
37127
14
76,0
24,0
6,7
1 2,5
37101 6
1110,0
461,0
23,5
3 16
37128
12
105,0
38,0
7,2
1 4
37102 4
1450,0
720,0
28,5
3 25
37129
10
135,0
58,0
7,9
1 6
37103 2
2150,0
1008,0
32,0
3 35
37130
8
200,0
96,0
9,5
1 10
37104 1
2800,0
1440,0
37,0
3 50
37131
6
290,0
154,0
11,5
1 16
37105 2/0
3750,0
2016,0
42,0
3 70
37132
4
400,0
240,0
13,5
1 25
37106 3/0
4590,0
2736,0
43,3
3 95
37133
2
560,0
336,0
15,0
1 35
37107 4/0
5400,0
3456,0
49,0
3 120
37134
1
730,0
480,0
17,5
1 50
37108 16
190,0
58,0
10,7
4 1,5
37135
2/0
1000,0
672,0
20,0
1 70
37109 14
270,0
96,0
12,3
4 2,5
37136
3/0
1250,0
912,0
22,5
1 95
37110 12
380,0
154,0
14,0
4 4
37137
4/0
1650,0
1152,0
24,0
1 120
37111 10
520,0
230,0
15,5
4 6
37138
300 kcmil
2000,0
1440,0
25,2
1 150
37112 8
955,0
384,0
21,0
4 10
37139
350 kcmil
2460,0
1776,0
27,6
1 185
37113 6
1400,0
614,0
25,5
4 16
37140
500 kcmil
3050,0
2304,0
30,6
1 240
37114 4
1950,0
960,0
31,0
4 25
37141
600 kcmil
3700,0
2880,0
33,5
1 300
37115 2
2650,0
1344,0
35,0
4 35
37142
16
130,0
29,0
8,5
2 1,5
37116 1
3600,0
1920,0
41,0
4 50
37143
14
190,0
48,0
10,2
2 2,5
37117 2/0
4890,0
2688,0
46,5
4 70
37144
12
260,0
77,0
11,8
2 4
37118 3/0
6180,0
3648,0
51,6
4 95
37145
10
350,0
115,0
13,1
2 6
37119 4/0
7200,0
4608,0
56,1
4 120
37146
8
550,0
192,0
17,7
2 10
37120 16
225,0
72,0
11,2
5 1,5
37147
6
900,0
307,0
20,2
2 16
37121 14
335,0
120,0
13,3
5 2,5
37148
4
1300,0
480,0
24,3
2 25
37122 12
470,0
192,0
15,6
5 4
37149
16
150,0
43,0
9,5
3 1,5
37123 10
645,0
288,0
17,5
5 6
37150
14
205,0
72,0
11,0
3 2,5
37124 8
1150,0
480,0
22,9
5 10
37151
12
330,0
115,0
13,0
3 4
37125 6
1690,0
768,0
26,4
5 16
37152
10
470,0
173,0
14,5
3 6
37126 4
2400,0
1200,0
32,0
5 25
37153
Dimensions and specifications may changed without prior notice.
mm²
Part no. permitted tensile stress
per mm² conductor N
Ⴠ Minimum bending radius
flexing
up cable cable Ø
> 8-12 cable cable Ø
> cable cable Ø
fixed installation
up cable cable Ø
> cable cable Ø
Application
Tauchflex-R special cable for use connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and has
proven its worth for constant use drinking water, process water and service water immersion depth 300 m. AWG-No.
weight
kg km
Outer Ø
approx.
Tauchflex-R can also installed for use dry, damp and humid areas well the open air.5
Ⴠ Ⴠ
Special cables corresponding apapted to
DIN VDE 0250/DIN VDE 0285-525-2-21/
DIN 50525-2-21
Good insulation properties when submerged
in water
Ⴠ Minimal weight gain under water
Ⴠ Temperature range (max.5, IEC 60228 cl. mm
No. temperature
for the outer surface) -40°C +80°C
Ⴠ Core insulation EPR The mechanical stability the insulation
materials remains constant even when
submerged
Ⴠ Core identification DIN VDE 0293
Ⴠ Temperature limit water:
max. Not suitable for the installation hazardous areas. (RI01)
Water resistant Cables
270
.5, fine-wire,
BS 6360 cl.
Ⴠ Cores standed layers with
optimal lay-length
Ⴠ Outer sheath special EPR
Note
Ⴠ Sheath colour blue
Ⴠ Permissible operating temperature
at conductor +90°C
Ⴠ with green-yellow conductor
x without green-yellow conductor
Ⴠ Nominal voltage U0/U 450/750 AWG sizes are approximate equivalent
values. +60°C
with limited duration life
Temperature limit air:
flexible -25°C +80°C
fixed installation -40°C +80°C
Ⴠ GN-YE conductor, cores and above
Ⴠ rotor-connection cable for motors to
1000 with protected fixed installation in
tubes.
Ⴠ Operating voltage
at alternating and three-phase currents
U0/U 413/825 V
at direct currents U0/U 619/1238 V
Ⴠ Test voltage 2,5 kV, min
Ⴠ Max. mm
No.
Weight
approx.
mm²
Part no.
Weight
approx. The actual cross-section mm².
AWG-No.
kg km
Cop.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
weight
kg km
Outer Ø