Poznámky redaktora
They are also
used for mining industry, surface mining, stone-pits, building sites, outdoors well indoors.
U0/U 0,7/1,2 kV
Direct current system
U0/U 0,9/1,8 kV
Ⴠ oils
Ⴠ fats and chemicals
Ⴠ GN-YE conductor, cores and above Tests
Ⴠ Cores stranded layers with
optimal lay-length
Ⴠ Behaviour fire
to DIN VDE 0482-332-1-2
DIN 60332-2-1, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Inner sheath rubber
compound type GM1b to
DIN VDE 0207 part 21
Ⴠ Test voltage 3000 V
Ⴠ Insulation resistance
min. (RF01)
246
Allweather, Rubber and Liftcables
.
weight
kg km
Outer Ø
max. Suitable for fixed installation plaster dry,
damp and wet areas.cores x
cross-sec.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
6
336,0
154,0
13,5
1 16
38001 2
2777,0
1344,0
42,5
4 35
38023
1
3817,0
1920,0
49,0
4 50
38024
4
473,0
240,0
16,5
1 25
38002
2
635,0
336,0
18,0
1 35
38003 2/0
5071,0
2688,0
53,5
4 70
38025
3/0
6636,0
3648,0
61,5
4 95
38026
1
866,0
480,0
20,0
1 50
38004
2/0
1145,0
672,0
22,0
1 70
38005 4/0
7000,0
4608,0
68,0
4 120
38027
3/0
1475,0
912,0
25,0
1 95
38006 16
252,0
72,0
17,0
5 1,5
38028
4/0
1832,0
1152,0
27,5
1 120
38007 14
362,0
120,0
20,0
5 2,5
38029
300 kcmil
2000,0
1440,0
30,0
1 150
38008 12
509,0
192,0
23,0
5 4
38030
350 kcmil
2450,0
1776,0
34,0
1 185
38009 10
798,0
288,0
26,5
5 6
38031
500 kcmil
3190,0
2304,0
37,0
1 240
38010 8
1120,0
480,0
30,0
5 10
38035
14
205,0
48,0
16,0
2 2,5
38011 6
1680,0
768,0
34,0
5 16
38036
4
2430,0
1200,0
42,0
5 25
38037
16
173,0
43,0
15,0
3 1,5
38012
16
470,0
101,0
19,5
7 1,5
38038
14
247,0
72,0
16,5
3 2,5
38013
12
336,0
115,0
20,0
3 4
38014 14
546,0
168,0
21,5
7 2,5
38032
10
520,0
173,0
22,0
3 6
38015 16
560,0
144,0
22,0
10 1,5
38039
16
210,0
58,0
16,0
4 1,5
38016 14
851,0
288,0
28,0
12 2,5
38033
14
305,0
96,0
19,0
4 2,5
38017 14
1230,0
432,0
33,0
18 2,5
38040
12
415,0
154,0
21,5
4 4
38018 14
1260,0
466,0
33,5
19 2,5
38034
10
641,0
230,0
23,0
4 6
38019
8
1113,0
384,0
27,5
4 10
38020
6
1412,0
614,0
37,0
4 16
38021
4
2095,0
960,0
39,0
4 25
38022
Dimensions and specifications may changed without prior notice. The insulation plastic-rubber compound
on EPR basis improves the resistance ozone order avoid the formation cracks due ozone and insulation damages switch-boards.cores x
cross-sec.NSSHÖU heavy dusty rubber cable 0,6/1kV
Properties
Cable structure
Technical data
Ⴠ Tinned copper-conductor, to
DIN VDE 0295 cl.5, fine-wire,
BS 6360 cl. AWG-No.
AWG-No. MOhm Oil resistant DIN 60811-404
Ⴠ Outer sheath rubber
compound type 5GM5 to
DIN VDE 0207 part 21
Ⴠ Tensile strength
statical load: total
cross-section x15 N/mm²
Note
Ⴠ with green-yellow conductor
x without green-yellow conductor
Ⴠ Sheath colour yellow
Ⴠ Minimum bending radius
fixed installation cable Ø
flexing 10x cable Ø
without forced operation 15x cable Ø
Ⴠ AWG sizes are approximate equivalent
values. Not suitable for drumming and use all types of
machinery, such robots, handling units and energy transfer units, where constant mobility essential.
Weight
approx.5
Ⴠ Ⴠ
Rubber sheath cable to
DIN VDE 0250 part 812
Ozone resistance
Ⴠ High insulation resistance
Ⴠ Temperature range
flexing -25°C +80°C
fixed installation -40°C +80°C
Ⴠ Resistant against hot penetration
Ⴠ Core insulation rubber (EPR)
compound type 3GI3 to
DIN VDE 0207 part 20
Ⴠ Low abrasion
Ⴠ High notch resistant
Ⴠ Permissible operating temperature
at conductor +90°C
Ⴠ The code identification single core
sheathed insulated wire black.
Application
Are suited connecting cable for very high mechanical stress underground mining and tools for use industries and outdoor use. long duration life guaranteed under extreme operating conditions.
mm²
Part no.c. The actual cross-section mm².
kg km
Cop.
Ⴠ Core identification DIN VDE 0293-308
- cores coloured
- from cores, black with continuous
white numbering
Ⴠ Nominal voltage U0/U 0,6/1 Resistant against
Ⴠ Operating voltage in
three-phase and one-phase a.
weight
kg km
Outer Ø
max. mm
No.
Weight
approx. mm
No.
mm²
Part no.5, IEC 60228 cl.
kg km
Cop