Poznámky redaktora
U0/U 318/550 V for direct current U0/U 413/825 V Ⴠ with green-yellow conductor x without green-yellow conductor Ⴠ AWG sizes are approximate equivalent values. Ⴠ Test voltage 2000 V Ⴠ Minimum bending radius 7,5x cable Ø Ⴠ H05RN-F replaced former type NMHÖU mm². max.no. These cables can used contact with fats and oils (for example deep fryer). They are also suitable for fixed installation, for example furniture, decoration covering, partition walls and hollow spaces prefabricated building parts. Weight approx. operating voltage three-phase and one-phase a. 36008 national type: A05 RN-F Art-no. H05RN-F These cables are suitable for connecting electrical equipment with low mechanical stress dry, damp and wet places well open air, for example as connection cable for horticulture tools. mm No. They are not suitable for use open air, industries (also permitted tailor workshops and that kind) agriculture plants and for connecting commercial electrical tools. mm² Part no. 36007 (A)05 RN-F, outer sheath colour grey, for window shades manufacturer Ⴠ Further sizes are available request.5, IEC 60228 cl. Application H05RR-F These cables are suitable for connecting electrical appliances, for example vacuum cleaner, flat irons, soldering irons, kitchen appliances, toaster, stoves etc. weight kg km Outer Ø min.c. kg km Cop. (RF01) 241 Allweather, Rubber and Liftcables F .H05RR-F H05RN-F rubber-sheathed cable Properties Cable structure Technical data Ⴠ Bare copper-conductor, to DIN VDE 0295 cl. weight kg km Outer Ø min. at 1,5 mm² not VDE; adapted VDE (H)05 RN-F Art. These cables are suitable for fixed installation partition walls, furniture, decoration covering and hollow spaces prefabricated building parts. kg km Cop. They were also used for medium mechanical stress households and offices. 19 60,0 14,4 5,7 7,4 2 0,75 35001 19 78,0 14,4 5,7 7,4 2 0,75 36001 19 74,0 21,6 6,2 8,1 3 0,75 35005 19 94,0 21,6 6,2 8,1 3 0,75 36003 19 78,0 29,0 6,8 8,8 4 0,75 35009 19 90,0 29,0 6,8 8,8 4 0,75 36007 19 90,0 29,0 6,8 8,8 4 0,75 36008 19 99,0 36,0 7,6 9,9 5 0,75 35019 18 94,0 19,0 6,1 8,0 2 1 36002 18 72,0 19,0 6,1 8,0 2 1 35002 18 114,0 29,0 6,5 8,5 3 1 36004 18 85,0 29,0 6,5 8,5 3 1 35006 16 157,0 43,0 8,6 11,0 3 1,5 36005 18 98,0 38,0 7,1 9,3 4 1 35010 16 228,0 72,0 10,5 13,5 5 1,5 36006 18 134,0 48,0 8,0 10,3 5 1 35020 16 98,0 29,0 7,6 9,8 2 1,5 35003 16 120,0 43,0 8,0 10,4 3 1,5 35007 16 150,0 58,0 9,0 11,6 4 1,5 35011 16 180,0 72,0 9,8 12,7 5 1,5 35013 14 145,0 48,0 9,0 11,6 2 2,5 35004 14 170,0 72,0 9,6 12,4 3 2,5 35008 14 220,0 96,0 10,7 13,8 4 2,5 35012 14 270,0 120,0 11,9 15,3 5 2,5 35014 12 260,0 115,0 11,3 14,5 3 4 35015 12 340,0 154,0 12,7 16,2 4 4 35017 10 361,0 173,0 12,8 16,3 3 6 35016 10 462,0 230,0 14,2 18,1 4 6 35018 Dimensions and specifications may changed without prior notice. H05RN-F H05RR-F AWG-No.cores x cross-sec. Ⴠ H05RR-F replaced the former type NLH and NMH 2,5 mm². max.5, fine-wire, BS 6360 cl.5 Ⴠ Ⴠ to DIN VDE 0285-525-2-21 / DIN 50525-2-21, IEC 60245-4 Oils and fats are allowed come touch Tests Ⴠ H05RR-F additionally 6500 Behaviour fire to DIN VDE 0482-332-1-2 DIN 60332-2-1, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) Ⴠ Core insulation rubber EI4 to DIN VDE 0207-363-1 DIN 50363-1 Ⴠ Temperature range -30°C +60°C Ⴠ Core identification DIN VDE 0293-308 Ⴠ Permissible operating temperature at conductor +60°C Cores laid up Note Ⴠ Outer sheath black: RR-F Rubber, EM3 to DIN VDE 0207-363-2-1/DIN 50363-2-1 RN-F EM2 to DIN VDE 0207-363-2-1/DIN 50363-2-1 Ⴠ Nominal voltage U0/U 300/500 V Ⴠ Max. The installation in hazardous areas allowed. mm No. mm² Part no. Weight approx.cores x cross-sec. AWG-No. = The product conformed with the Low-Voltage Directive 2006/95/EC. The actual cross-section mm²