Poznámky redaktora
Core insulation braided glass-fibre
impregnated with silicone
Note
Ⴠ Further sizes are available request. AWG-No.
kg km
Max.
Weight
approx.cores x
cross-sec. The special
construction the cable designed for recommended maximum temperature damp environmentsof 220°C and for dry environments above this
temperature.
mm
No.cores x
cross-sec. The actual cross-section mm².
Weight
approx. (RE01)
229
Heat resistant Cables
E
Suitable accessories can found Chapter X. cores without GN-YE conductor
2 BU, BN
3 BK, BU, BN
4 BK, BU, BN, WH
5 BK, BU, BN, WH, RD
6 BK, BU, BN, WH, RD, GY
7 BK, BU, BN, WH, RD, GY, GN
Ⴠ Test voltage 2500 screened analogue type:
MULTITHERM 400-ES, confer page 236
Ⴠ Minimum bending radius
5x cable Ø
Ⴠ Overall lay cores
Ⴠ Outer sheath braided glass-fibre
impregnated with silicone
Application
MULTITHERM 400 cables are used for applications where extremely high connecting and ambient temperatures can arise, iron and steel works,
rolling mills, foundries, glass and ceramic factories, furnace and power plant construction, during thermoplastic moulding processes etc.
20
47,0
3,3
10,0
6,2
2 0,5
51741 16
128,0
8,6
58,0
9,1
4 1,5
51761
16
150,0
8,3
72,0
10,0
5 1,5
51762
20
50,0
3,1
15,0
6,4
3 0,5
51742
20
70,0
3,0
19,0
7,5
4 0,5
51743 16
175,0
8,0
88,0
10,7
6 1,5
51763
16
190,0
7,8
101,0
11,0
7 1,5
51764
20
81,0
2,9
25,0
8,0
5 0,5
51744
20
97,0
2,8
30,0
8,6
6 0,5
51745 14
135,0
12,2
48,0
9,2
2 2,5
51765
20
105,0
2,7
34,0
8,7
7 0,5
51746 14
153,0
11,6
72,0
9,7
3 2,5
51766
19
55,0
5,1
14,4
6,7
2 0,75
51747 14
190,0
11,2
96,0
10,6
4 2,5
51767
14
230,0
10,8
120,0
11,8
5 2,5
50060
19
66,0
5,1
21,6
7,0
3 0,75
51748
19
86,0
4,9
29,0
8,0
4 0,75
51749 14
270,0
10,4
144,0
12,8
6 2,5
50061
14
295,0
10,1
168,0
13,0
7 2,5
50062
19
103,0
4,7
36,0
8,8
5 0,75
51750
19
119,0
4,5
43,0
9,5
6 0,75
51751 12
191,0
16,0
77,0
11,0
2 4
50063
19
130,0
4,4
50,0
9,7
7 0,75
51752 12
224,0
15,3
115,0
11,4
3 4
50064
18
63,0
7,0
19,0
6,9
2 1
51753 12
285,0
14,6
154,0
13,0
4 4
50065
12
360,0
14,1
192,0
14,5
5 4
50066
18
82,0
6,7
29,0
7,8
3 1
51754
18
98,0
6,4
38,0
8,3
4 1
51755 12
485,0
13,3
270,0
16,5
7 4
50067
18
119,0
6,2
48,0
9,1
5 1
51756 10
340,0
20,0
173,0
14,2
3 6
50068
18
138,0
6,0
58,0
9,8
6 1
51757 10
442,0
19,0
230,0
16,2
4 6
50069
18
150,0
5,8
67,0
10,0
7 1
51758 10
535,0
18,0
288,0
17,7
5 6
50070
16
87,0
9,4
29,0
8,0
2 1,5
51759 8
710,0
26,0
384,0
20,0
4 10
50071
16
103,0
9,0
43,0
8,3
3 1,5
51760 6
990,0
34,0
615,0
24,5
4 16
50072
Dimensions and specifications may changed without prior notice.
Ⴠ AWG sizes are approximate equivalent
values. permiss.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
AWG-No.
mm²
Part no.
mm
No.
weight
kg km
Outer Ø
approx.MULTITHERM 400 halogen-free
Properties
Cable structure
Technical data
Ⴠ Copper-conductor nickel plated,
fine-wire (ASTM 355)
Ⴠ Ⴠ
Special core insulation
for high temperatures
Asbestos and cadmium-free
Ⴠ Temperature range
-60°C +400°C
(for short time +500°C)
Ⴠ Core insulation braided glass-fibre
impregnated with silicone
2.
Ⴠ Nominal voltage 500 V
Ⴠ Core identification
- No.
mm²
Part no. permiss.
kg km
Max.
weight
kg km
Outer Ø
approx. cores with GN-YE conductor
3 GN-YE, BU, BN
4 GN-YE, BK, BU, BN
5 GN-YE, BK, BU, BN, WH
6 GN-YE, BK, BU, BN, WH, RD
7 GN-YE, BK, BU, BN, WH, RD, GY
- No.
currentcarrying
capacity
at +340°C (A)
Cop.
• Cable protection tube HTP
.
currentcarrying
capacity
at +340°C (A)
Cop