HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 228 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
recommended for the application the apparatus which are moving during the operation with less mechanical stress. mm No. mm² Part no. mm No.cores x cross-sec. Weight approx.5, fine-wire, BS 6360 cl. 19 59,0 14,4 5,7 7,4 2 0,75 22290 19 63,0 14,4 6,7 8,4 2 0,75 22343 19 75,0 21,6 7,2 9,1 3 0,75 22344 19 71,0 21,6 6,2 8,1 3 0,75 22291 19 93,0 28,8 6,8 8,8 4 0,75 22292 19 99,0 28,8 7,8 9,8 4 0,75 22345 19 120,0 36,0 8,6 10,9 5 0,75 22346 19 113,0 36,0 7,6 9,9 5 0,75 22293 18 71,0 19,2 7,1 9,0 2 1 22347 18 67,0 19,2 6,1 8,0 2 1 22294 18 86,0 29,0 6,5 8,5 3 1 22295 18 91,0 29,0 7,5 9,5 3 1 22348 18 111,0 38,4 8,1 10,3 4 1 22349 18 105,0 38,4 7,1 9,3 4 1 22296 18 129,0 48,0 8,0 10,3 5 1 22297 18 137,0 48,0 9,0 11,3 5 1 22350 16 91,0 29,0 7,6 9,8 2 1,5 22298 16 97,0 29,0 8,6 10,8 2 1,5 22351 16 117,0 43,0 9,0 11,4 3 1,5 22352 16 110,0 43,0 8,0 10,4 3 1,5 22299 16 137,0 58,0 9,0 11,6 4 1,5 22300 16 145,0 58,0 10,0 12,6 4 1,5 22353 16 175,0 72,0 10,8 13,7 5 1,5 22354 16 165,0 72,0 9,8 12,7 5 1,5 22301 14 159,0 48,0 10,0 12,6 2 2,5 22355 14 150,0 48,0 9,0 11,6 2 2,5 22302 14 170,0 72,0 9,6 12,4 3 2,5 22303 14 180,0 72,0 10,6 13,4 3 2,5 22356 14 224,0 96,0 11,7 14,8 4 2,5 22357 14 211,0 96,0 10,7 13,8 4 2,5 22304 14 255,0 120,0 11,9 15,3 5 2,5 22305 14 270,0 120,0 12,9 16,3 5 2,5 22358 12 251,0 115,0 11,3 14,5 3 4 22306 12 266,0 115,0 12,3 15,5 3 4 22359 12 350,0 154,0 13,7 17,2 4 4 22360 12 330,0 154,0 12,7 16,2 4 4 22307 10 402,0 173,0 13,8 17,3 3 6 22361 10 379,0 173,0 12,8 16,3 3 6 22308 10 494,0 230,0 14,2 18,1 4 6 22309 10 524,0 230,0 15,2 19,1 4 6 22362 Dimensions and specifications may changed without prior notice. mm² Part no. weight kg km Outer Ø min. max. max.H05SS-F H05SST-F heat-resistant multicore cable Properties Cable structure Technical data Ⴠ Tinned copper-conductor, to DIN VDE 0295 cl. (RE01) 226 Heat resistant Cables Suitable accessories can found Chapter X. Ⴠ Ⴠ Temperature range fixed installation -60°C 180°C (for short time +250°C) Core insulation cross-linked rubber (SiR) compound type EI2 to DIN VDE 0207-363-1 DIN 50363-1 Ⴠ Core identification DIN VDE 0293-308 Ⴠ Permissible operating temperature at conductor +180°C GN-YE conductor, cores and above Tests Ⴠ Nominal voltage U0/U 300/500 Cores stranded layers with optimal lay-length Behavior fire: Test vertical flame-propagation to VDE 0482-332-1-2, DIN 60332-1-2, not valid for the cables with outer polyesterbraiding (Type H05SST-F) Ⴠ Test voltage 2000 V Ⴠ Outer sheath cross-linked rubber compound type EM9 to DIN VDE 0207-363-2-1/DIN 50363-2-1 Ⴠ Specific volume resistivity min. avoid this, it should treated with great care during the installation and application the cable. The actual cross-section mm². 200 MOhm km Ⴠ Minimum bending radius flexing 7,5x cable Ø fixed installation cable Ø Ⴠ Sheath colour black (RAL 9005) also available other colours request Note H05SST-F Ⴠ Radiation resistance up 20x106 cJ/kg (up Mrad) Constuction per H05SS-F with green-yellow conductor x without green-yellow conductor Ⴠ Polyester braiding Ⴠ AWG sizes are approximate equivalent values.5 Ⴠ Ⴠ Heat-resistant multicore cable to DIN VDE 0285-525-2-83 / DIN 50525-2-83 Advantages Hardly changes dielectric strength and the insulation resistance also at high temperatures Ⴠ These cables may damaged pulling over sharp-edges abrasion during the installation and application. These cables are installed for fixed installation, mechanical protected, for internal wiring lighting fixtures industrial application. kg km Cop. Weight approx. AWG-No. H05SST-F H05SS-F AWG-No. weight kg km Outer Ø min.5, IEC 60228 cl. = The product conformed with the Low-Voltage Directive 2006/95/EC. kg km Cop. Application Multicore cables insulated and sheathed with heat resistant silicone rubber without strain relieving elements are used high temperatures with contact hot-surfaces.cores x cross-sec. • Cable protection tube HTP