Poznámky redaktora
recommended for the application the apparatus which are moving during the operation with less mechanical stress.
mm
No.
mm²
Part no.
mm
No.cores x
cross-sec.
Weight
approx.5, fine-wire,
BS 6360 cl.
19
59,0
14,4
5,7 7,4
2 0,75
22290 19
63,0
14,4
6,7 8,4
2 0,75
22343
19
75,0
21,6
7,2 9,1
3 0,75
22344
19
71,0
21,6
6,2 8,1
3 0,75
22291
19
93,0
28,8
6,8 8,8
4 0,75
22292 19
99,0
28,8
7,8 9,8
4 0,75
22345
19
120,0
36,0
8,6 10,9
5 0,75
22346
19
113,0
36,0
7,6 9,9
5 0,75
22293
18
71,0
19,2
7,1 9,0
2 1
22347
18
67,0
19,2
6,1 8,0
2 1
22294
18
86,0
29,0
6,5 8,5
3 1
22295 18
91,0
29,0
7,5 9,5
3 1
22348
18
111,0
38,4
8,1 10,3
4 1
22349
18
105,0
38,4
7,1 9,3
4 1
22296
18
129,0
48,0
8,0 10,3
5 1
22297 18
137,0
48,0
9,0 11,3
5 1
22350
16
91,0
29,0
7,6 9,8
2 1,5
22298 16
97,0
29,0
8,6 10,8
2 1,5
22351
16
117,0
43,0
9,0 11,4
3 1,5
22352
16
110,0
43,0
8,0 10,4
3 1,5
22299
16
137,0
58,0
9,0 11,6
4 1,5
22300 16
145,0
58,0
10,0 12,6
4 1,5
22353
16
175,0
72,0
10,8 13,7
5 1,5
22354
16
165,0
72,0
9,8 12,7
5 1,5
22301
14
159,0
48,0
10,0 12,6
2 2,5
22355
14
150,0
48,0
9,0 11,6
2 2,5
22302
14
170,0
72,0
9,6 12,4
3 2,5
22303 14
180,0
72,0
10,6 13,4
3 2,5
22356
14
224,0
96,0
11,7 14,8
4 2,5
22357
14
211,0
96,0
10,7 13,8
4 2,5
22304
14
255,0
120,0
11,9 15,3
5 2,5
22305 14
270,0
120,0
12,9 16,3
5 2,5
22358
12
251,0
115,0
11,3 14,5
3 4
22306 12
266,0
115,0
12,3 15,5
3 4
22359
12
350,0
154,0
13,7 17,2
4 4
22360
12
330,0
154,0
12,7 16,2
4 4
22307
10
402,0
173,0
13,8 17,3
3 6
22361
10
379,0
173,0
12,8 16,3
3 6
22308
10
494,0
230,0
14,2 18,1
4 6
22309 10
524,0
230,0
15,2 19,1
4 6
22362
Dimensions and specifications may changed without prior notice.
mm²
Part no.
weight
kg km
Outer Ø
min. max. max.H05SS-F H05SST-F heat-resistant multicore cable
Properties
Cable structure
Technical data
Ⴠ Tinned copper-conductor, to
DIN VDE 0295 cl. (RE01)
226
Heat resistant Cables
Suitable accessories can found Chapter X.
Ⴠ Ⴠ
Temperature range
fixed installation -60°C 180°C
(for short time +250°C)
Core insulation cross-linked rubber (SiR)
compound type EI2 to
DIN VDE 0207-363-1 DIN 50363-1
Ⴠ Core identification DIN VDE 0293-308
Ⴠ Permissible operating temperature
at conductor +180°C GN-YE conductor, cores and above
Tests
Ⴠ Nominal voltage U0/U 300/500 Cores stranded layers with
optimal lay-length Behavior fire:
Test vertical flame-propagation to
VDE 0482-332-1-2, DIN 60332-1-2,
not valid for the cables with outer
polyesterbraiding (Type H05SST-F)
Ⴠ Test voltage 2000 V
Ⴠ Outer sheath cross-linked rubber
compound type EM9 to
DIN VDE 0207-363-2-1/DIN 50363-2-1
Ⴠ Specific volume resistivity
min. avoid this,
it should treated with great care during
the installation and application the cable. The actual cross-section mm². 200 MOhm km
Ⴠ Minimum bending radius
flexing 7,5x cable Ø
fixed installation cable Ø
Ⴠ Sheath colour black (RAL 9005)
also available other colours request
Note
H05SST-F
Ⴠ Radiation resistance
up 20x106 cJ/kg (up Mrad) Constuction per H05SS-F with green-yellow conductor
x without green-yellow conductor
Ⴠ Polyester braiding
Ⴠ AWG sizes are approximate equivalent
values.5
Ⴠ Ⴠ
Heat-resistant multicore cable to
DIN VDE 0285-525-2-83 /
DIN 50525-2-83
Advantages Hardly changes dielectric
strength and the insulation resistance also
at high temperatures
Ⴠ These cables may damaged pulling
over sharp-edges abrasion during the
installation and application. These cables are installed for fixed installation, mechanical protected, for internal wiring lighting fixtures industrial
application.
kg km
Cop.
Weight
approx. AWG-No.
H05SST-F
H05SS-F
AWG-No.
weight
kg km
Outer Ø
min.5, IEC 60228 cl.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
kg km
Cop.
Application
Multicore cables insulated and sheathed with heat resistant silicone rubber without strain relieving elements are used high temperatures with
contact hot-surfaces.cores x
cross-sec.
• Cable protection tube HTP