5, 6360 cl. 85% coverage
Ⴠ Max. Tinned copper braided screen,
approx. For deviating ambient temperatures
the conversion factors should used and
for further see the indication in
DIN VDE 0298 part 4. supply and connecting cable for medium mechanical stresses fixed installations and forced movements dry, moist and
wet environments.
= The product conformed with the Low-Voltage Directive 2006/95/EC.
Ⴠ Radiation-resistance
up 80x106 cJ/kg (up Mrad)
Application
This TOPFLEX®-EMV-UV-2XSLCH-J motor power supply cable for the frequency converters assures electromagnetic compatibillity plants and
buildings, facilities with units and operating equipment where the fields electromagnetic interference might cause adverse effects the surroundings. Installation hazardous areas. For the installation conduit
all precautions must taken that accumulation water can occur the pipes.5,
IEC 60228 cl. 200 MOhm km
Ⴠ with meter marking
Note
Ⴠ Coupling resistance
acc.
Continuation Ⴇ
213
Motor-, Servo and Feedback Cables
D
.
EMC Electromagnetic compatibillity
The screen must connected both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements 55011. Used the automotive and food industries, environmental
technology, packaging industry, machine tools. These cables are suitable for outdoor applications and underground using conduits tubes.TOPFLEX®-EMV-UV-2XSLCH-Jforpowersupplyconnectionstofrequency
converters, halogen-free, double screened, higher current carrying capacity, 0,6/1kV, meter marking
Properties
Cable structure
Technical data
Ⴠ Bare copper, fine wire conductor to
DIN VDE 0295 cl. to
EN 55011 and DIN VDE 0875 part 11
Ⴠ AWG sizes are approximate equivalent
values.
Tests
Ⴠ self-extinguishing and flame retardant
acc. 250 Ohm/km
Ⴠ **) The current carrying capacity for
permanent operation ambient temperature
of 30°C. operating voltage
A. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps,
ventilators, conveyor belts and air-conditioning installations and similar applications. and 3-phase 700/1200 V
DC operation 900/1800 V
Ⴠ Due the optimal screening an
interference-free operation frequency
converters obtained
Ⴠ Outer sheath special polyolefin compound
Ⴠ Test voltage 4000 Sheath colour black (RAL 9005)
Ⴠ The materials used manufacture are
cadmium-free and contain silicone
and free from substances harmful to
the wetting properties lacquers
Ⴠ Insulation resistance
min.
Respecting the permissible operating temperature the conductor +90 permits higher current carrying capacity than insulated power
distribution cables. The actual cross-section mm². different cross-sections
max.C.5
Ⴠ Ⴠ
Special motor power supply cable for
frequency converters adapted to
DIN VDE 0250
halogen-free
Ⴠ Low mutual capacitance
Ⴠ Low coupling resistance for high
electromagnetic compatibility
Ⴠ Ⴠ
Temperature range
flexing -5°C +90°C
fixed installation -40°C +90°C
Core insulation cross-linked
polyethylene (XLPE) This screened motor supply cable with
low mutual capacitance the single cores
because the special XLPE core insulation
and low screen capacitance enable low-loss
transmission the power compared to
PE-sheathed connecting cables
Ⴠ Core cidentification: BN, BL, GY
Ⴠ Permissible operating temperature
at conductor +90°C
Ⴠ GN-YE conductor
Ⴠ Cores stranded concentric layers
Ⴠ Nominal voltage U0/U 600/1000 Screen with special aluminium film
2. DIN VDE 0482-332-1-2,
DIN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Ⴠ Minimum bending radius
free-movement for outer Ø:
up mm: 10x cable Ø
> 12-20 mm: 15x cable Ø
> mm: 20x cable Ø
fixed installation for outer Ø:
up mm: cable Ø
> 12-20 mm: 7,5x cable Ø
> mm: 10x cable Ø
Ⴠ Meets EMC requirements acc