Harting Sbírka katalogů říjen 2013

| Kategorie: Katalog  | Tento dokument chci!

Vydal: HARTING s.r.o. Autor: HARTING

Strana 9 z 808

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
2: Han® 3A (108 contacts contact) (108 contacts contact) 2. For all other (not standardized) rectangular connectors, the number poles can chosen freely.1 Number Contacts The pole number (number contacts) important consideration when selecting connector for certain application. 2. DIN 43652 specifies the design and number contacts for only four types of connectors. 2.1: Han® 108 Fig. The assumed conductor cross-sections can found the derating diagram (power loss curve). . Usually, you must take into account that only useful contacts are counted. the connector has a protective contact (PE), should counted separately. Also, certain arrangements have become common.1.2 Current The rated current (current-carrying capacity) another selection criterion.1.Criteria for Selecting Connectors 23 2 Criteria for Selecting Connectors 2.1 Electrical Criteria 2. The manufacturer’s specification relates the current, which all connector contacts can carry simultaneously. Examples Fig