Harting Sbírka katalogů říjen 2013

| Kategorie: Katalog  | Tento dokument chci!

Vydal: HARTING s.r.o. Autor: HARTING

Strana 9 z 808

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
1.1. For all other (not standardized) rectangular connectors, the number poles can chosen freely. Also, certain arrangements have become common. Usually, you must take into account that only useful contacts are counted. The assumed conductor cross-sections can found the derating diagram (power loss curve). The manufacturer’s specification relates the current, which all connector contacts can carry simultaneously. 2.1: Han® 108 Fig.1 Electrical Criteria 2.2 Current The rated current (current-carrying capacity) another selection criterion.Criteria for Selecting Connectors 23 2 Criteria for Selecting Connectors 2.2: Han® 3A (108 contacts contact) (108 contacts contact) 2. . 2.1 Number Contacts The pole number (number contacts) important consideration when selecting connector for certain application. DIN 43652 specifies the design and number contacts for only four types of connectors. Examples Fig. the connector has a protective contact (PE), should counted separately