Final assembly the contacts.
. tighten the locking screw, hexagonal wrench size needed. After the assembly the modules the housing, the tightning torque of
the locking screw can checked and corrected necessary.
Insert the hexagonal wrench the mating side the contact.5
Nm).
Therefore important that the corresponding modules are assembled
in the correct position mating not possible.Special Applications 195
5.3 Assembly manual for Han®HC Modular 350 A
Fig. Due the hexagonal slot, each module can be
used different positions (turning every degrees). The locking screw
has tightened with the recommended tightning torque that is
determined the conductor's cross section (6-14 Nm).
The user should make sure that the cable adequately strain reliefed to
protect the contact from radial stress. The heads the fixing screws have face the mating
direction the module.3.43 44: Mounting instructions
1. the
same time, push the conductor over the axial screw. Push the conductor through the cable gland and the housing. Insert the
stripped end the conductor into the termination entry the module
until the insulation touches the contact.
5. Strip the conductor length 19+1 mm
2.2. 5.
3. Once all modules are terminated, they are mounted into the housing by
means two metal frames (tightning torque the fixing screws 0. This possibility
can used create coding system.
6.
4. The modules have hexagonal around which mates with the
metal frame