Harting Sbírka katalogů říjen 2013

| Kategorie: Katalog  | Tento dokument chci!

Vydal: HARTING s.r.o. Autor: HARTING

Strana 164 z 808

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
198: Example current-carrying capacity graph The derating factor justified because the current-carrying capacity may be limited further external factors, e.g.Corrected current-carrying capacity curve (derating curve) A corrected current-carrying capacity curve (derating curve), derived from the [.. This curve takes into account variations specimens as well errors temperature measurements the measuring equipment.. In many cases, the individual terminals can carry several times the derated current indicated the derating curve when less than % of the total complement used. 4. For these cases, general rules cannot established and the limits must determined for each individual case. recommended that the method described this standard used accordingly these cases.197), shall specified the relevant detail specification. the size the wire and unequal distribution the loaded circuits. NOTE: practice, usually the case that all terminals are not loaded simultaneously with the maximum permissible current. these factors result current- carrying capacity other than that which may expected due thermal limitations, then revised value shall apply. . 158 ____________________________________________________________ 0 fu3 <u2 tu\ Ambient temperature Fig.] basic curve (see figure 4