Furse Earthing & lightning protection

| Kategorie: Katalog  |

Vydal: ABB s.r.o.

Strana 16 z 132

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
Jointing clamps will ensure low resistance, corrosion resistant connection between air termination and down conductors.e. – Air termination network The air termination network the point of connection for lightning strike. Use the guidelines IEC/BS 62305-1 -3 for the correct placement conductors. High strength pits are available plastic and concrete.e. cable armouring, gas, water or steam piping, entering the building should also be bonded directly possible the earth termination network. — 04 Air rod bases. — 12 Equipotential bonding SPDs. Electrodes can constructed individually from earth rods, earth plates, flat tape, stranded cable or any combination these. typically consists meshed conductor arrangement covering the roof the structure. Earth rod clamps Select high copper content alloy earth rod clamp for the connection the earthing conductor the earth rod. The mesh size is determined Lightning Protection Level LPL. Type Type foundation electrode. 8.g.e. All metallic services, e. – Down conductor network 6. All continuous metalwork should be considered for bonding. — 10 Earth inspection pits. Earth electrodes Choose earth electrode suit the system design i. . – Earth termination network The means dissipating the current the general mass earth.g. 7. — 05 Interconnection components. — 03 Air terminals. 3. This will ensure that the vertical air rods are both solidly fixed the fabric the structure and have low resistance connection the conductor network. — 07 Test clamps. brick, stone, plastic and metal. — 13 Main aspects and individual components of external lightning protection system. Earth inspection pits Select earth inspection pit protect the earth electrode connections. Fixings are available for a wide range modern construction materials, e. Air rod bases Choose the correct air rod base. 4. 9. 5. Air terminals Use air terminals the form vertical air rods for the protection prominent roof top features or equipment.FURSE® EARTHING LIGHTNING PROTECTION QUALIT SOLUTIONS FOR SAFEGUARDING PEOPLE, STRUCTURES AND SERVICES — Introduction lightning protection Product selection guide – Conductors The first choice faced the designer a structural lightning protection system is the type conductor system used: • Choose the material required, i. — 02 Fixings. Use strike pads connect and thus expose concealed conductors. Conductor jointing clamps Select component for the interconnection of multiple conductors for changes direction. Conductor network The conductor network the means of intercepting/carrying the current lightning strike safely the earth termination network. — 11 Bonds metalwork. copper or aluminium • Choose the type conductor required, i. — 09 Earth rod clamps. Interconnection components Crossover clamps have been specially designed for use where conductors cross part a roof network. Test clamps In order allow periodic disconnection and testing the earth termination network, select test clamp placed within the run each down conductor. — 08 Earth electrodes. 10. flat tape, solid circular stranded 1. 2. — 01 Conductor network. – Equipotential bonding Bonding the most commonly employed method avoiding the damaging effects of side flashing. — 06 Conductor jointing clamps. Fixings Select the correct system fixings for each part of the conductor system. this below ground application, the clamp must ensure good electrical contact and resist corrosion throughout the lifetime the installation