Down conductors Down conductors should within the bounds of practical constraints take the most direct route from the air termination system the earth termination system. This statement is reinforced within the 2011 version of IEC/BS 62305, being incorporated the body the standard, rather than forming part of an Annex (Annex IEC/BS 62305-3:2006). — Table Minimum thickness metal sheets metal pipes in air termination systems (IEC/BS 62305-3 Table 3). The down conductor spacing should correspond with the relevant class LPS. The greater the number of down conductors the better the lightning current is shared between them.5 mm Copper 0.— Technical reference IEC/BS 62305-3 Physical damage to structures life hazard Non-conventional air termination systems A lot technical (and commercial) debate has raged over the years regarding the validity the claims made the proponents such systems.7 mm (1) Thickness prevents puncture, hot spot ignition. Typically the air rod tall then the only claim for the zone protection afforded this air rod would based and the relevant class LPS and not any enhanced dimension claimed some nonconventional air rods. (2) Thickness only for metal sheets not important prevent puncture, hot spot ignition problems. Lateral connections sometimes referred as coronal bands ring conductors provided either by fortuitous metalwork external conductors at regular intervals are also encouraged. air rod) shall be determined only the real physical dimension of the air termination system. Down conductors should wherever possible installed each exposed corner of the structure research has shown these carry the major part the lightning current. This enhanced further by equipotential bonding the conductive parts the structure.g. Natural components When metallic roofs are being considered a natural air termination arrangement, IEC/BS EN 62305 offers guidance the minimum thickness and type material under consideration, well as additional information the roof has be considered puncture proof from lightning discharge (see Table 6). Class LPS Material Thickness(1) t Thickness(2) t’ I Lead 2.5 mm Aluminium 0. This topic was discussed extensively within the technical working groups that compiled IEC/BS 62305. IEC/BS 62305 states unequivocally that the volume zone protection afforded the air termination system (e. The outcome was remain with the information housed within this standard.5 mm Titanium 0. There should always minimum two down conductors distributed around the perimeter of the structure.65 mm Zinc 0. 112 FURSE® EARTHING LIGHTNING PROTECTION QUALIT SOLUTIONS FOR SAFEGUARDING PEOPLE, STRUCTURES AND SERVICES .0 mm Steel (stainless, galvanized) 4 0. There other standard being contemplated to run parallel with this standard IEC/BS 62305