BD FE180 E30-E90 MM“ VDE REG.80 max.pyrofil® Keram JE-H(St)H. System circuit integrity guaranteed operating voltage 110V. 225V Halogen-free, with improved fire characteristics with reference VDE 0815 Circuit integrity (FE180) accordance with VDE 0472-814, IEC 60331, 50200 System Circuit integrity E30-E90* accordance with DIN 4102-12
Separator Plastic tape zero halogen Insulation Crosslinked polymer zero halogen
Preventive fire protection
BRANDMELDEKABEL
Sheath FRNC/LS0H
Shielding Al-laminated tape zero halogen
Drain wire 0,8 mm
Conductor Solid
Product information
Application
Safety cables
Safety cables are used all situations that require special protection against fire and flame damage for people and equipment and where high degree safety conditions must fulfilled. A/C IEC 61034-1/-2, 61034-1/-2 (EN 50268-1/-2), VDE 0482-1034-1/-2 (VDE 0482-268-1/-2) IEC 60331-11/-23 (180 minutes), VDE 0472 part 814, 50200, VDE 0482-200 DIN 4102 part 12, NBN 713.Bd FE180 E30-E90
Fire alarm cable max. Suitable for indoor applications. For outdoor applications, protection must provided against exposure direct sunlight.Bd FE180/E30-E90 Keram BMK 0708/e
Accessories
during installation permanent installation 1000 N/10 Impacts permanent installation during installation
7,5 outer diameter) 2,5 D
-30°C +70°C -5°C +50°C
IEC 60754-2, 50267-2-2, VDE 0482-267-2-2 IEC 60332-1-2, 60332-1-2, VDE 0482-332-1-2 IEC 60332-3-22/-24 Cat. Permitted operating temperature conductor +70˚C. 200 pF/100m 800 max..2 Ω/km 0. These cables correspond the demands system circuit integrity E30-E90* accordance with DIN 4102-12. 100 max. A/C, 50266-2-2/-4 Cat.” „METRE MARKING“ min. 225 500 Core/Core 2000 50Hz, Core/Screen
Construction
Support systems
Fixing devices
Sheath colour Imprint
Electrical Properties
Firestop systems
Insulation resistance Loop resistance Capacitance unbalance Kapazitive Kopplung Rated volage Test voltage
Distribution boxes
General Properties
Minimum bending radius Crush resistance Impact Operating temperature Zero halogen non corrosive gases Flame retardant Fire resistant (no flame propagation) Minimum smoke emission Circuit integrity (FE180) System Circuit integrity E30-E90*
pyrofil® JE-H(St)H. The cable should only laid directly earth water protective conduit used.. A/C, VDE 0482-266-2-2/-4 Cat. Conductor Insulation Core colours Separator Shielding Outer sheath Bare copper, solid, 0.
. 73.8mm Flame retardent polyolefin compound according VDE 0819 part 107, 50290-2-27 and VDE 0250-214 „HM red DAETWYLER PYROFIL KERAM „BRANDMELDEKABEL“ JE-H(ST)H....8mm diameter, according VDE 0815 Fire-resistant, crosslinked, high-performance Keram special-compound accordance with VDE 0266 „HXI According VDE 0815, bundles identified numbered tape PEPT “Plastic Tape” Al-laminated tape with tinned copper drain wire 0. 120 nF/km 800 max.
* Circuit integrity dependent installation method. NO.9361 „ORDER NO.020 (Rf 11/ 2
Informations
P-78
Technical changes reserved.