System circuit integrity guaranteed operating voltage 400V. A/C IEC 61034-1/-2, 61034-1/-2 (EN 50268-1/-2), VDE 0482-1034-1/-2 (VDE 0482-268-1/-2) Circuit integrity (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472 part 814, 6387 CWZ System Circuit integrity E90 DIN 4102 part System Circuit integrity under effect water VdS 3423 ≥16mm2]
Accessories
Technical changes reserved.
. The cable should only laid directly earth water protective conduit used. A/C, VDE 0482-266-2-2/-4 Cat. NR.pyrofil® Keram (N)HXCH FE180 E90
Safety low voltage cable 0.6/1kV Halogen-free, with improved fire characteristics With reference VDE 0266 and CENELEC 604 Circuit integrity (FE180) accordance with VDE 0472-814, IEC 60331 System Circuit integrity E90 accordance with DIN 4102-12
Concentric conductor Bare copper wire Insulation Crosslinked polymer zero halogen Conductor Solid/ stranded
Preventive fire protection
Sheath FRNC/LS0H
Separator Plastic tape
Reinforcing helix Bare copper tape
Filler Flame retardant, zero halogen
Fire barrier High-peformance Keram compound
Product information
Application
Safety cables
Safety cables are used all situations that require special protection against fire and flame damage for people and equipment and where high degree safety conditions must fulfilled. A/C, 50266-2-2/-4 Cat. Permitted operating temperature conductor +90˚C. For outdoor applications, protection must provided against exposure direct sunlight.
Construction
Support systems
Conductor Insulation Filler Concentric conductor Separator Outer sheath Core colours Sheath colour Imprint
Bare copper, solid stranded IEC 60228, 60228, (VDE 0295) Double insulation, cross-linked, high-performance Keram special compound according VDE 0266 “HXI1” Halogenfree, compound plastic tape Bare copper wires with reinforced helix Plastic tape Polyolefin compound according CENELEC 604 and VDE 0276-604 “HM4” According CENELEC 308 and VDE 0293 orange DAETWYLER PYROFIL KERAM (N)HXCH FE180 E90 1kV MM2” VDE REG.” “YEAR” “METRE MARKING” 0. 7780 “VDS“ “ORDER NO. These cables correspond the demands system circuit integrity E90 accordance with DIN 4102-12. Suitable for indoor applications.6/1kV 4000V, 50Hz
Fixing devices
Firestop systems
Electrical Properties
Nominal voltage Test voltage
General Properties
Minimum bending Radius Operating temperature Zero halogen non corrosive gases Flame retardant Fire resistant (no flame propagation) Minimum smoke emission
Distribution boxes
during and permanent installation (multicore cable) outer diameter) permanent installation -45°C +90°C during installation -5°C +50°C
P-70
pyrofil® (N)HXH FE180/E30-E60 0708/e0708/e (N)HXCH FE180/E90 KeramKeram FE180/E90 Keram 0708/e
Informations