g. further highlight, the modular highdensity distribution system also allows mixed assembly. The optoversal® cable (single-mode, multimode) used trunk cable that assembled both sides with the corresponding number MPO plugs via splitter. 2x4 Cartridges 0,5 Fibre optic cabling
Copper unscreened
When ordering pre-assembled cables, note that the length the supplied trunk cable always based the longest cable assembly.g.
U-255
Informations
Accessories
MHD Copper Distributor Cartridge 0,5 U
MHD Distributor Cartridge 0,5 U
Systems
MHD
MHD Cu-Trunks with Cu-Cartridge RJ45
MHD Cu-Trunks with Telco jack
MHD FO-Trunks with MPO connectors
Fibre optic
consists zero-halogen and screen trunk cables pre-assembled with the 50-pin screen telco socket with very slim design and flexible for wide range applications. this system, copper ports can terminated single rack unit, for example., LCD) mounted the front. Cartridges Copper data cabling Variant consists the breakout twisted pair (TP) cable (uninet® 7002 4P) which connected both sides with cartridge. All components are available stainless steel black finish.
MHD-Housing 19‘‘/3 for max. For MHD trunks, this means that the length the pre-assembled cable between the ferrules must indicated the longest lashes. This solution supports transfer rate Gbit/s with maximum permanent link length Copper data cabling Variant 2
MHD-Housing 19‘‘/1 for max.
is based the standard MPO plug connector system for fibres.
Copper screened
Communication technology
. meet these demands, modular cabling system was developed which allows both preassembled copper connections and connections contained enclosure system featuring extremely high packing density. The ready-to-use, pre-assembled cartridges feature MPO coupler the back which serves input and connected internally via fibres with the standard couplers (e., access control and air conditioning), the electric power supply (UPS), any active devices and, course, the cabling system. The distribution system composed two different enclosure models one three rack units where the distributor cartridges are mounted. This cartridge contains printed circuit board with LSA plus contacts. This applies the building (e. Technical changes reserved. The maximum link length for transmission speed Gbit/s m. Since data centres are constantly growing and changing, cabling systems must accommodate changes, moves and addons, often during running operation, the shortest time possible without the need for on-site work and using in-house staff whenever possible.MHD Modular High Density distributor system
for use data centres
A data centre must set way that ensures the level data security required the operator