1,000 CAT IV
Accessories / Replacement parts
3 leads for 10/15 kV > P01295465 Blue lead with crocodile clip > P01295468 Red lead with crocodile clip > P01295469 Black lead with crocodile clip > P01295470 Blue lead with crocodile clip > P01295471 Red lead with crocodile clip > P01295472 Black lead with crocodile clip > P01295473 leads for 10/15 kV, black/blue/red crocodile clips > P01295466 lead with rear connection > P01295467 > P01295454Z moulded test probes (red/black) crocodile clips (red/blue/black) > P01103062 USB optical cable HX0056-Z Carrying bag P01298066 C.Digital insulation testers
C.99 Yes automatic Programmable 0.A 6550
Specifications Test voltages Insulation measurement Ranges kV
N INSULATIO 15 kV kV
]] Short-circuit current: Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs, well fixed adjustable voltage Multiple test modes: voltage ramp and step with "burn-in", "early break" and limit" modes filters optimize measurement stability Automatic filter for measurements strong electromagnetic fields
]] C.A 6550 & C.001-9.2 5 mA di/dt minutes :59 seconds Continuous testing PI, DAR, DD, SV, (ppm/V) Yes filters with time constants R(t)+u(t); i(t); i(u) 256 recordings, 80,000 points and date Optically-isolated port for USB and RS232 links DataView® NiMH rechargeable batteries, 1.999 10.00-49.2 4,000 mAh charging external voltage: 90-260 50/60 1,000 cat IEC 61010-1 and IEC 61557 406 330 174 mm, approx.A 6555
]] C.A 6555 delivered with carrying bag containing 2 safety leads long with plugs (red/blue), guarded safety cable long equipped with plug one end and plug with rear connection the other end (black), crocodile clips (red, blue, black), CAT 1,000 test probes (red/black) for voltage measurements, 1 rear-connector lead (blue), 1 mains power cable 2 m long, DataView® software, 1 optical USB communication lead, 1 operating manual 5 languages CD-ROM
References order
> C.A 6555 > P01139705 > P01139706
Portable, on-site and laboratory test and measurement instruments 2012 catalogue
Page 55
.A 846 thermo-hygrometer P01156301Z mains lead P01295174
State delivery
> 6550 and C. Measurement display filter Graphs display Storage Communication software Power supply Electrical safety Dimensions weight
15 kV 500 1,000 2500 5 000 15 TW 10,000 25 TW 15 000 500 1,000 2,500 500 1,000 2,500 5,000 10,000 5,000 10,000 15,000 10,000 15,000 presettable voltage values presettable voltage values Variable: 40-15 kV Variable: 40-10 Increment: 1 kV: Increment: 1 kV: 1 kV kV: 100 1 kV 15 kV: 100 presettable ramps: start voltage end voltage duration 40-1100 500-10,000 40-1100 500-15,000 steps (value and duration configurable for each step) AC: 2,500 DC: 4,000 0.A 861 thermometer, thermocouple P01650101Z C.A 6550 C.A 6555
Fixed test voltages Variable test voltages Variable voltage settings Ramp mode Ramp configuration range Step mode Voltage measurement after test Capacitance measurement 500 Leakage current measurement Discharge after test I-limit Additional test stop modes Early-break Timer Burning mode Burning Ratio calculation Calculation ref