LABORATORY AND EDUCATIONAL INSTRUMENTATION
Training case
Power and harmonics case
> ower and Harmonics case isk-free simulation network and three-phase load ariable currents and voltages ariable phase shift ariable harmonic distortion
]] Power and harmonics case
Specifications Network simulations Measurement simulations Voltage Current Voltage variation* Current phase shift* Harmonic distortion for current and voltage* Phase output Power supply Electrical safety Dimensions weight
* phase 1
SINGLE THREE-phase (230 mains power supply) W/h, var, THD,… Mains 15 % 10, 10 % + 8 %; −10 % 30°, 45°, 60° ± 5° inductive capacitive Network level, 15 %, 25 % and variable Yes 230 mains socket IEC 61010 300 Cat pollution 490 395 x 195 mm kg
State delivery
> elivered with mains lead D
Accessories / Replacement parts
> hoice current sensors: AmpFLEXTM, clamps, etc.: Contact us
Reference order
P ower and harmonics case P01NC5003