About Fluke Biomedical
Fluke Biomedical leads the world in the manufacture of biomedical test and simulation products, including standalone electrical safety testers to fully integrated and automated performance testing and documentation systems. Fluke Biomedical also provides some of the most trusted and accurate radiation safety, medical imaging, and oncology quality-assurance solutions for regulatory compliance.
Service
Fluke Biomedical is dedicated to providing the best service within the healthcare industry. Equipped with the bestcredentialed facilities, onsite experts, and full asset-management capabilities, Fluke Biomedical's service team is always on call to take care of its customers. Fluke Biomedical's world-class staff leads the industry in post- and pre-sale support, including helping customers choose the best products and accessories for their needs, technical support, product calibration, and repairs.
Strana 36 z 451
«
Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.
»
Jak získat tento dokument?
Poznámky redaktora
FLUKE Non-Invasive Blood Pressure Simulator Specifications
Autosequences five user-programmable sequences test NIBP monitors with specific series cuffLink performance tests, including static pressure test, leak test, and pop-off test eight adult-neonatal-arrhythmia dynamic NIBP selections, each which can cycled times during the sequence Printable test report Displayed real-time parameters Instantaneous cuff pressure: mmHg 300 mmHg Peak cuff pressure: mmHg 500 mmHg peak Inflate/deflate time: 0.82 (15 lb)
B iom edical
Included accessories
2242915 Operator's Manual 2392381 Adult Cuff Mandrel Spacer Blocks 2230305 Adult Cuff Mandrel End Blocks (qty 2392328 External Cuff Mandrel Neonatal (truncated plastic cylinder diameters: 10, and cm) 2245300 CuffLink Adapter Kit 2198846 Hospital Grade Power Cord Set 2248408 Soft Vinyl Accessory Pouch
Ordering information
CuffLink Non-Invasive Blood Pressure Simulator 2246985 United States, 120 2399820 2399835 2399873 2399858 2399864 2399847 Australia, 250 Denmark, 250 India, 250 Israel, 250 Italy, 250 Schuko, 250 V
Model Wrist cuff simulations ECG syncronized Leak test Over pressure test Manometer medTester compatible
BP Pump 2
CuffLink
Yes Option Yes Yes Yes No
No Yes Yes Yes Yes
2399886 Switzerland, 250 2399899 United Kingdom, 250 V
36
. Generation normal, bradycardia, and tachycardia rhythm selections with wide range user-programmable peripheral pulse amplitudes (weak, normal and strong). Compatible with oscillometric NIBP devices. Preprogrammed target value selections: Adult systolic/diastolic (MAP) (mmHg): 60/30 (40), 80/50 (62), 100/65 (75), 120/80 (90), 150/100 (115), 200/150 (165) and 255/195 (215) Neonatal/pediatric systolic/diastolic: above selections, excluding 255/195 and 200/150 Repeatability: selected target value Adult arrhythmia selections: Baseline NIBP target value: (120/80) (NSR) Atrial fibrillation (A-Fib) Premature atrial contraction (PAC) Premature ventricular contraction (PVC) Missed beat (MB) Aberrant sinus conduction (AS) Preprogrammed peripheral pulse waveforms: Pulse amplitude MAP: mmHg (typical adult value) Pulse volume range: 5.1 31.1 999.9 mmHg/s Total measurement time: 999.0 mmHg steps over maximum range 300 mmHg increase decrease dynamic pressure values Vertical axis: relative amplitude shifted increments over maxi mum range from 200 simulate weak, normal, and strong peripheral pulses Environmental Operating temperature: (59 °F) Storage temperature: (32 122 °F) Dimensions (LxWxH) Weight 38.1 Pulse rise time: (min) Heart rates (adult and neonate): BPM, BPM, BPM, BPM, 120 BPM, 160 BPM, 200 BPM, and 240 BPM Heart-rate accuracy: selected rate Pre-programmable target value shifts: Horizontal axis: preprogrammed target value selections shifted 1.1 mmHg/s 999.75 12.9 max Selected heart rate: Selected systolic/diastolic (mean) target values User-programmed vertical and horizontal shifts Dynamic non-invasive Simulation range normal, hypertensive and hypotensive dynamic blood pressure noninvasive blood pressures for typical adult, infant, and neonatal patients.5 in) 6.9 Inflate/deflate rate: 0.7 (15 12