BERKER Wiring accessories + Building automation catalogue 2012

| Kategorie: Katalog  | Tento dokument chci!

The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 560 z 616







Poznámky redaktora
- Passive glass breakage detectors single glazing (these detectors are triggered when coin tapped against the window) „ All alarm system components accessible from outside must protected against sabotage. Temperature differences these areas can trigger alarm. - Selecting the position motion detectors: Motion detectors should not directed towards heating air-conditioning equipment, fax machines, automatic lights, windows areas with strong air movement. motion detectors 90° with total cable length max. Closed kOhm Open 100 kOhm 0 180 sec. protect apartments smaller properties. They supplement mechanical security measures., adjustable 0 °C IP20 165 215 mm 9020 Sabotage VDC Motion detector 90° +AL SAB - GND GTAL SAB S/U 9155 915501 9155019155 Alarm central unit, wired .1 m min. 9020 Max.4 V=, order no. 100 m white + NCC TTAMP V InternalExternal Armed Not armed Net Exterio r In terio r 24 h Arm Sabotage 24h 915501 „ Burglar alarm systems are used signal attempts break early possible., which provide the greatest possible resistance against burglars.25 L max. All property protection based mechanical security measures such strong doors and windows, additional bolts etc. A max.g.4 sec.T43 For individual connection wiring see continuous line. damage doors and windows, quickly as possible. - False alarms can result call-out costs. - Wired motion detector 90° Alarm Alarm Sabotage VDC + NCC TTAMP V - Wired motion detector 90° Alarm Sabotage VDC Technical data Operating voltage Current input Emergency power supply Output voltage for external devices Fuse for outputs flashing light and siren Loading capacity the outputs Load capacity alarm, status outputs Buzzer volume Pulse length for inputs Input switching Siren duration Arm/alarm delay Operating temperature Index protection Dimensions D) Order no. „ Alarm sensors should installed clearly visible but out reach.g.: 921401 12 V= T 1. mA 85 dBA distance 0. „ Burglar alarm systems should installed such way that they detect and signal the attempts break in, e. ~~ ~~ Motion detector 90° wired alarm centre The wired alarm centre permits the setup low-cost alarm system using only wired components, e. „ Switching devices should electronically protected against sabotage. 0., adjustable 0 sec. „ Burglar alarm systems must installed such way that false alarms are possible: - Every false alarm weakens security system loses credibility.: Alarm system wired 230 V~, V= 10 mA~ mA= possible with battery pack: 14. „ Measures for prevention false alarms: - Positive operation when armed, with alarm delay time: The alarm delay time means that, upon entering the property, you have time (adjustable between and 60 seconds) disarm the alarm centre before the alarm triggered. AC 230 V~ Sabo Siren - Flash - Siren Status + V L1, external L2, internal L3, h L4, Sabo Armed not armed GND K1K2 GND GND GND + Ext Int F1 T1A Wired alarm centre Potential-free alarm contact and sabotage contact with 4-stage sensitivity enhance functional safety. For multiple connections open point and wire (see dotted line). The control centre must housed specially secured location