The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.
The shutter remains closed until command
is sent from the associated control mounting. number
Cable length
Order No.6 mm, connect shield ground!
0169
Brightness sensor for suction attachment
RolloTec glass breakage sensor
The glass breakage sensor affixed the window pane.:
RolloTec brightness sensor
at approx., and affix the sensor the window pane with
special LOCTITE adhesive (see operating instructions)
Technical data
Contact
Switching capacity
Action radius
Contact resistance load
Alarm condition
Alarm duration
Connection cable
Temperature range
Index protection
Max.
Lay sensor cable far from
230 cables possible. MOhm
approx.
approx 000 Lux, fixed
approx..
RolloTec inserts: operation several RCDs
Individual control Individual controlMaster control
Cut-off relay
MM
To avoid unwanted tripping the RCDs,
the circuits must decoupled. 1000 000 Lux, programmable
approx.
External brightness sensor
Technical data
Maximum sensitivity diode
Sunlight brightness values
Comfort push-button with radio button sensor connection
Memory button with sensor connection
Timer with sensor connection
Twilight brightness values (only timer 1775.
RolloTec brightness sensors
By connecting the RolloTec brightness sensors surface-mounted the RolloTec insert
the sun protection function can implemented.
L
N
N2
1
L
2975
N L
2925
N2
1
L
2975
N2
1
L
2975
L
2911
Ø mm
2 m
25 mm0169
27
84,5
61
25
0184
20 mm
0-20 mm19 mm
2 mm
Height mm
0170
RolloTec
. the brightness
remains below the pre-set level for minutes, the shutter raised again. 0. Attachment: clean the surface the
glass with spirit methyl alcohol etc.
Sensor connection options RolloTec inserts
a)
Connect wire marked
grey ground
Magnet/Glass
Ground
Brightness
b)
Connect wire marked
grey ground
Magnet/Glass
Ground
Brightness
c)
N L
2925
Terminal block Terminal block
Lay the sensor cable far from
230 cables possible.5 sec. Rinse the sensor clean
water and affix the window glass.
0170
RolloTec glass breakage sensor
Mounted on
window pane
The glass breakage sensor can connected three different ways. Master commands are not executed,
and brightness values are not processed.
LIYY 0. 0169
If the sunlight value (20 000 Lux programmable see technical data) exceeded
by minutes, the shutter automatically moves down until the sensor concealed;
then moves little until the sensor exposed once more. This connection can detached any time order prevent
unwanted lowering (e. balcony door shutters) (not with magnetic contact).
(See sensor connection options)
For attaching the window pane,
we recommend the glass metal
adhesive set made Loctite.g. attach, clean the glass with
meths similar, and the sensor with washing liquid.
Various options are available for connecting the sensors (brightness sensor magnetic contact glass breakage sensor):
a) The sensor cable can routed easily from the flush-mounted wall box through the tunnel the RolloTec insert far the terminal block and securely
connected.:
RolloTec glass breakage sensor
1pole NCC contact
max.
b) The sensor cable can fed through the cable duct between the base plate and the flush-mounted wall box and fixed the terminal block.
The sun protection function only activated when the shutter has been moved to
its end position continuous run operation. the glass broken, the
shutter automatically lowered, thereby protecting the property from the weather
and from unauthorised intrusion. 850 nm
approx. the pre-set Lux value exceeded, the
shutter lowered such that slits light still come through.
The shutter lowered about minutes after the brightness has fallen below the
programmed level. with telephone cable
J-Y(ST)Y 0.
Twilight function:
The twilight function (only with timer) activated approx.
Sensors must not connected in
parallel multiple RolloTec inserts. Ohm
min. with telephone cable
J-Y(ST)Y 0. 5000 000 Lux, prog.14 mm2
-30 °C
IP66
10 units (in series)
2 extendable approx. minutes before sunset
(see astronomical curve). 300 Lux, programmable
-30 °C
IP54
2 extendable approx.T39
N2
1
L
2975
N2
1
L
2975
N L
2925
Sun protection function: with brightness sensor order no.)
Temperature range
Index protection
Cable length
Order No.
c) For mounting, the sensor cable connector can plugged into the lower sensor connection.6 mm, connect shield ground. 350 mW
2 metres
max