The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 530 z 616

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
100 m Cut-out with auto. 10 BLC relay switch insert HVAC Extension unit cable length Power consumption Fuse Radio interference suppression Operating temperature Connecting terminals Order no. Push-buttons (NOCs) can only illuminated via phase and neutral conductor. Use BLC controller extension unit only combination with BLC controller BLC presence detector the BLC Tronic switch insert. W Bulb-preserving soft start Technical data Nominal voltage Connected load Power consumption Switch-on BLC Triac switch insert LV Extension units Extension unit cable length Fine-wire fuse Radio interference suppression Operating temperature Connecting terminals Order no. 0185.1 W BLC extension unit and push-button (NOC) unlimited BLC controller extension units max. transformers loading) incl. 2. transformer power loss 750 (inductive) Fluorescent lamps uncompensated 500 VA, Duo circuit 1000 (inductive) Mixed load, capacitive and inductive loads should not mixed incandescent lamps 800 W 230 halogen lamps 750 W motor switching current 2. 10 max. Extension unit operation only possible there a cover fitted the BLC Triac switch insert. 10 max. N L N L When energy-saving lamps and electronic ballasts are connected note high switch-on currents, necessary use making current limiter order no.5 mm2 or 1.5 mm2 Technical data Nominal voltage Connected load potential-free suitable for extra-low voltage function (AC) Minimum load Extension units Basic circuit 1 L 2905 BLC Triac switch insert LV L N 1 LN 29085031 1 L 2907 1 L 2905 BLC Triac switch insert LV Operation with extension units L N 230 V~, 50/60 Hz Incandescent and 230 halogen lamps 40-400 W Conv.5 mm2 Technical data Nominal voltage Connected power channel 1 Connected power HVAC channel Potential-free L N L N L N L N L N L N L Operation with extension units 1 L 2907 5031 1 L 2916 BLC Tronic switch insert BLC extension unit Push-button (NOC) To other extension units 1 LN 2908 BLC controller extension unitN L Basic circuit 1 L 2916 BLC Tronic switch insert N L L N L N BLC Tronic switch insert for BLC button, BLC radio button, BLC presence detector and BLC controller BLC Triac switch insert for BLC button, BLC radio button, BLC presence detector and BLC controller BLC relay switch insert with potential-free contact for BLC button, BLC radio button, BLC presence detector and BLC controller BLC relay switch insert HVAC for BLC button, BLC radio button, BLC presence detector and BLC controller To other extension units Basic circuit 1 LN 2906 BLC relay switch insert L N BLC relay switch insert for BLC button, BLC radio button, BLC presence detector and BLC controller Operation with extension units 1 LN 2908 1 LN 2906 5031 1 L 2907 BLC relay switch insert L N To other extension units To other extension units To other extension units N L BLC extension unit Push-button (NOC) BLC extension unit Push-button (NOC) BLC extension unit Push-button (NOC) BLC controller extension unit BLC controller extension unit BLC controller extension unit BLC extension unit Push-button (NOC) BLC controller extension unit Push-buttons (NOCs) can only illuminated via phase and neutral conductor. Extension unit operation only possible there a cover fitted the BLC relay switch insert. 100 m Via circuit-breaker to 55015 5 °C Screw-type terminals for max. When energy-saving lamps and electronic ballasts are connected note high switch-on currents, necessary use making current limiter order no. 1. HVAC channel min. 1.T13 BLC Tronic switch insert Extension unit cable length Short-circuit-proof Overheating protection Radio interference suppression Operating temperature Connecting terminals Order no.5 mm2 or 1. cut-out to 55015 -20 25°C (see operating conditions, Page T6) Screw-type terminals for max. 2. When energy-saving lamps and electronic ballasts are connected note high switch-on currents, necessary use making current limiter order no. 0185. W Bulb-preserving soft start BLC extension unit and push-button (NOC) unlimited BLC controller extension units max. 2/10/30/60/120 min. 10 The potential-free terminals should be connected from the rear 1 LN L 290610 BLC relay switch insert with potential-free contact Basic circuit Potential-free NOC 1 LN L 290610 1 LN 29085031 1 L 2907 BLC relay switch insert with potential-free contact Operation with extension units Potential-free NOC 230 50/60 Hz Incandescent lamps 800 W 230 halogen lamps 750 W 12 100 mA BLC extension units and push-button (NOC) unlimited BLC controller extension units max. Use BLC controller extension unit only combination with BLC controller BLC presence detector the BLC relay switch insert with potential-free contact. 10 max.5 mm2 Technical data Nominal voltage Connected load The potential-free terminals (HVAC) should be connected from the rear 1 LN 2 10 30 60 L 2912 120 BLC relay switch insert HVAC L Basic circuit 1 LN 29085031 1 L 2907 1 LN 2 10 30 60 L 2912 120 BLC relay switch insert HVAC Operation with extension units M N 230 50/60 Hz Incandescent and 230 halogen lamps 1000 (ohmic) Tronic transformer 750 (capacitive) Conv. 290610 max. 2. 0185.5 mm2 230 50/60 Hz Incandescent and 230 halogen lamps 2300 (ohmic) Tronic transformer 1500 (capacitive) Conv. 2916 max. restart within sec.6 250 V to 55015 -20 (see operating conditions, Page T6) Screw-type terminals for max.5 mm2 Technical data Nominal voltage Connected load Power consumption Switch-on Extension units 230 V~, 50/60 Hz Incandescent and 230 halogen lamps and halogen lamps with Tronic transformer and mixed load specified load types 50-420 W approx.5 W HVAC channel approx. 100 m T 1.5 mm2 or 1. Use BLC controller extension unit only combination with BLC controller BLC presence detector the BLC Triac switch insert., can permanently switched off with BLC push-button BLC extension units and push-button (NOC) unlimited BLC controller extension units max. The potential-free contact suitable for function extra-low voltage FELV (alternating current)! Push-buttons (NOCs) can only illuminated via phase and neutral conductor.5 W Via circuit-breaker to 55015 5 °C Screw-type terminals for max. Use BLC controller extension unit only combination with BLC controller BLC presence detector the BLC relay switch insert. Push-buttons (NOCs) can only illuminated via phase and neutral conductor. Electronic protection (no change-over) by means autom. 100 m approx. Extension unit operation only possible there a cover fitted the BLC Tronic switch insert. 1. N L N L BLC switch inserts . transformer power loss 40-400 (inductive) Combination specified load types approx. 2905 BLC extension unit and push-button (NOC) unlimited BLC controller extension units max. Extension unit operation only possible there cover fitted on the BLC relay switch insert HVAC.1 A BLC relay switch insert HVAC Power consumption Switching OFF delay time Switching delay Extension units Extension unit cable length Fuse Radio interference suppression Operating temperature Connecting terminals Order no. Use BLC controller extension unit only combination with BLC controller BLC presence detector the BLC relay switch insert HVAC. transformer power loss 1000 (inductive) Fluorescent lamps uncompensated 1200 VA, parallel compensated 920 (induktive) Duo circuit 2300 (inductive) Mixed load; capacitive and inductive loads should not mixed BLC relay switch insert Power consumption Extension units Extension unit cable length Fuse Radio interference suppression Operating temperature Connecting terminals Order no. 2. 2. 2912 approx. transformers loading) incl. 100 m Via circuit-breaker to 55015 - (2000 °C) Screw-type terminals for max. transformers loading) incl.5 mm2 or 1. 2906 approx. The potential-free contact suitable for function extra-low voltage FELV (alternating current)! Push-buttons (NOCs) can only illuminated via phase and neutral conductor. Extension unit operation only possible there cover fitted on the BLC relay switch insert with potential-free contact.5 mm2 or 1