BERKER Wiring accessories + Building automation catalogue 2012

| Kategorie: Katalog  | Tento dokument chci!

The use of innovations and new technologies at Hageris always customer-driven. Every year, Hager evaluatesthousands of its customer contacts, resulting in detailedknowledge of its customers’needs in order to workefficiently and successfully.

Vydal: HAGER ELECTRO s.r.o. Autor: EN HAGER

Strana 526 z 616

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
2819.5 250 according 55015 5 (see operating conditions, Page T6) Plug-in terminals for max. 10 Phase cut-on Technical data Nominal voltage Connected load LV boosters built-in Dimming principle Rotary dimmer with rotary off switch 2819. 85% rated load. 289505) Low noise T 2. 2. 100 mA Phase cut-on Low noise D 3.15 250 to 55015 5 (see operating conditions, page T6) Plug-in terminals for max. L Switch-off N L Rotary dimmers RL N 3037 red 3036 LL 2875 red 3036 LL 2875 Rotary dimmer with soft lock Changeover switching Rotary dimmers Change-over switch L N Intermediate switching Rotary dimmers Change-over switchIntermediate switch N L R Switch-off LL 2875 N L Rotary dimmers L N L N L N 2885 L L 2885 L L 3037 red 3036 red 3036 Rotary dimmer with soft lock Change-over switching Rotary dimmer Change- over switch L N Intermediate switching Rotary dimmer Change-over switch Intermediate switch N L 230/240 V~, Hz 230 Incandescent and halogen lamps 100-1000 W Combinations specified loads max. 2875 230 V~, Hz 230 Incandescent and halogen lamps 60-600 (60-450 W) Combination specified load types max. 10 Rotary dimmer with soft lock Switching current for base load mains de-coupler Dimming principle Noise Fine-wire fuse Radio interference suppression Operating temperature Terminals Technical data Nominal voltage Connected load LV boosters built-in R,L 2885 L L Switch-off N L Rotary dimmer L N L N L N Switch-off LL 2873 N L Terminal for mains de-coupler Rotary dimmer L N Changeover switching red 3036 LL 2873 N L Change- over switchRotary dimmer L N red 30363037 LL 2873 N L Intermediate switch Change-over switch Rotary dimmer L N In case excessive making currents, use making current limiters order no. 0185. Combination specified load types max. 2. 10 Phase cut-off Very low noise Technical data Nominal voltage Connected load LV boosters built-in Dimming principle Noise Rotary dimmer with soft-lock Short-circuit-proof Overload protected Radio interference suppression Operating temperature Terminals Order no.5 mm2 or 1.5 mm2 R,C L N L N L N Rotary dimmer . 2. 100 mA Phase cut-off Tronic rotary dimmer with soft lock Switch-on Noise Short-circuit-proof Overload protected Radio interference suppression Operating temperature Terminals Order no.5 mm2 or 1.75 mm2 R Rotary dimmer with soft lock Intermediate switching Order no. red 3036 3037 red 3036 A LL 2874 A LL 2874 Tronic rotary dimmer with soft lock Changeover switching N L Tronic rotary dimmer Change- over switch A LL 2874 Switch-off N L Tronic rotary dimmer Terminal for mains de-coupler Intermediate switching N L Tronic rotary dimmer Intermediate switch Change-over switch Technical data Nominal voltage Connected load Universal booster RMD Plus Tronic boosters built-in Switching current for base load mains de-coupler Dimming principle 230 V~, Hz 230 Incandescent and halogen lamps 20-525 W Tronic transformers 20-525 W Combination specified load types max. 2885 Cut-out with auto.5 mm2 (Rotary dimmer with soft-lock and setting knob Aquatec) Noise Fine-wire fuse Radio interference suppression Operating temperature Terminals Rotary dimmer with soft-lock Order no. 230 V~, Hz 230 Incandescent and halogen lamps 60-400 W Combinations specified loads max. 2873 max.6 250 according 55015 5 (see operating conditions, Page T6) Screw-type terminals for max.5 mm2 or 1.T9 Rotary dimmer with rotary off switch, order no. 10 Phase cut-on Low noise T 1. restart Electronic protection (no change-over) By power reduction to 55015 5 (see operating conditions, page T6) Screw-type terminals 0.. 20-500 VA total power output including transformer power loss must must not exceed 500 VA. transformers subject min. 2.. 500 W max. 10 max. restart Electronic protection (no change-over) By power reduction to 55015 5 (see operating conditions, page T6) Plug-in terminals for max.5 mm2 230 V~, Hz 230 Incandescent and halogen lamps 20-500 W Conv. 2874 Bulb-preserving soft start-up Very low noise Cut-out with auto.5 mm2 or 1.5 mm2 Technical data Nominal voltage Connected load LV boosters built-in Control principle Noise Fine-wire fuse Radio interference suppression Operating temperature Terminals (Order no