Poznámky redaktora
4 Error messages displayed pop-up windows All the messages that appear the display pop-up window are described below. = Information, action, excepting displaying the relay. 46/1 08 .7 |e Contact wear Contact wear prealarm Contact wear 80% |e prealarm Protection prealarm |e prealarm Protection prealarm I Warning threshold exceeded |2 Timing Timing protection L Is Timing Timing protection S I* Configuration Parameters inconsistency IA Configuration Relay key plug data inconsistency 12. The following symbols the warning signals have the following meanings: IA Warning signal Protection alarm mode, with trip (trip=off).6.12. Error message Description [a Password error [a Session impossible programming session cannot started due contingency (e. Alarm message Description Notes Contact wear Alarm for contact wear Contact wear 100% [S_ Alarm Alarm for protection Temperature outside range [a (TRIP OFF) Alarm for protection T [a LC1 Load Alarm for load control LC1 [a LC2 Load Alarm for load control LC2 [a Sensor Alarm for current sensor Sensor disconnected faulty là Warning signal Protection alarm, with trip (trip=off) là disconnected Trip Coil disconnected faulty I Rating Plug Rating Plug Error absent faulty IA Invalid date Clock information lost [a status state error Probable error Q26 and/or Q27 IA Installation Key Plug Error |a not defined Stateofcircuitbreakerinconsistent (Open/Closed) Probable error Q26 and/or Q27 IA Local Bus Local Bus error See par.3 Table error and warning messages All the messages which can shown the display relating incorrect configurations, generic alarms deriving from the protection functions and linked useful information are described below.g. Is Protection alarm mode, with trip end delay (trip=on). timer-controlled delay still elapsing) [a Value outside range Value beyond the established limits [a Exception Command temporarily unavailable [a Unavailable Function temporarily unavailable [a Invalid date Date has not been set [a Parameters revised Programming session concluded correctly [a Cancelled Programming session cancelled [a Failed Programming session rejected [a Failed 1001 Inconsistent thresholds protections and S [a Failed 1002 Inconsistent thresholds protections and S [a Failed 3001 Inconsistency language change Model 3447 A pparatus Emax DC S cale D 1SDH000635R0002 Page No.6. 12