• Normal starting means starting tim Difficult starting means accelerating time s. • the tables with MCCBs, these are fitted with the magnetic relay alone. - The starter derating factor depends the operating conditions thermal overload relays: Factor 0. • Each table defined for motor currents: 3-phase motors, 4-pole. Setting always carried out 12.8 applied Infor ambient temperature °C. The Complete ABB Offer ABB has acquired years experience with respect problems coordination and able make complete offer based tests performed in its qualified laboratories. ill! I! 1SBC101001C0202 8 . For example: r 1kA for AC-3 A r for IeAC-3 A r for IeAC-3 125 etc. This offer includes 400 500 690 networks. - Short-circuit condition tests: • prospective "r" currents These currents depend the rated operational current the starter (IeAC-3) and are given the standard (Table 11). Types Coordination IEC 60947-4-1 (EN 60947-4-1) defines two types coordination according the expected level service continuity.8 applied Infor ambient temperature °C.M. Tripping classes thermal O/L relays according IEC 60947-4-1 (EN 60947-4-1): and for types and for types.9 applied Infor ambient temperature °C.S. - MCCBs and MCBs: factor 0. Complete coordination for combination includes the following points: - Selectivity test between the overload relay and the short-circuit protection device SCPD.General Information Coordination with Short-circuit Protection Devices In compliance with standards IEC 60947-4-1 and 60947-4-1, define for the contactors and starters the type, rating and characteristics of the short-circuit protection devices SCPD which allow selective protection against overloads and ensure protection against short circuits.3 AC-3 that the transient current peak occurring during starting does not lead tripping. The risk contacts light welding acceptable. Applicable Standards IEC 60947-4-1 (EN 60947-4-1) precisely defines the different points considered order carry out correct coordination. A com plete data base coordination tables, according IEC 60947-4-1 (EN 60947-4-1), available the ABB Website. In the coordination tables, the following short-circuit protection devices are recommended: • Moulded case circuit-breakers (MCCBs) • Miniature circuit-breakers (MCBs) • Switch-disconnector-fuses (aM, and BS) • Manual Motor Starters (M. These two devices MUST coordinated with equipment capable providing protection against short circuit (SCPD: short-circuit protective device): typically circuit breaker with magnetic release only switch fuse. Acceptable extreme dam­ age for the switchgear divided into two types. Type short-circuit conditions, the contactor starter does not endanger persons installations and will not able then operate without being repaired having parts replaced.) General Remarks Applicable all Tables • Each table defined for maximum ambient temperature °C. Basic Functions Any starter designed to: - start motors, - ensure continuous functioning motors, - disconnect motors from the supply line, - guarantee protection motors against overloads. These are not necessarily part the starter. For higher temperatures, apply derating factor according the following rules: - Fuses: factor 0. Type short-circuit conditions, the contactor starter does not endanger persons installations and will able operate afterwards. The starter typically made switching device (contactor) and overload protection device (thermal overload relay TOR electronic overload relay EOR). • the rated prospective short-circuit current "Iq" This the maximum current that the combination can withstand, for example kA