Odpínače 16...125A popis vlastností technické parametry | Odpínače OT 16...125F s montáží na základnu nebo DIN lištu | výběrová tabulka objednací údaje rozměrové výkresy | Odpínače OT s montáží do panelu výběrová tabulka objednací údaje rozměrové výkresy ...
Poznámky redaktora
r
Safety switches
Ordering information
O T90..
230V 400V 500V 690V bottom knock-outs
[kW] [kW] [kW] [kW] side [pcs] 025,5 040,5 [kg]
30 2no+2nc 2no+2nc 0T90AAUR6AZ 1SCA022542R1840 22
37 2no+2nc 2no+2nc OT125EAUR6AZ 1SCA022542R5320 22
45 2no+2nc 2no+2nc 0T160EAUR6AZ 1SCA022542R5410 32
55 110 132 160 4no+2nc 4no+2nc 0T200KAUR6AZ 1SCA022542R5590 39
75 132 160 200 4no+2nc 4no+2nc 0T250KAUR6AZ 1SCA022542R5670 45
90 160 200 250 4no+2nc 4no+2nc OT315KAUR6AZ 1SCA022542R5750 45
110 220 280 355 4no+2nc 4no+2nc 0T400DAUR6AZ 1SCA022542R5830 48
180 355 400 560 4no+2nc 4no+2nc 0T630KAUR6AZ 1SCA022542R5910 85
C entries ith -flan entries
- red-yellow pistol type handle (I-O OFF indication)
- auxiliary contacts according the following table
- PE-terminal
- cable entries with C-flange entries, blank entry plate top, both entry plates fixed,
the entry plates are also used for mounting the safety switch
- cover flanges, (delivered unfastened), the number cover flanges the table below.630
Steel sheet enclosed safety switches with cable entries, 6-pole, IP65
Cable entries from bottom
Divided cable entries ith ring-flange entries
The delivery includes:
- red-yellow pistol type handle (I-O OFF indication)
- auxiliary contacts according the following table
- PE-terminal
- divided cable entry with ring-flange entries bottom blank entry plate top,
both entry plates fixed, the entry plates are also used for mounting the safety switch
- ring-flange covers with knock-out openings, (delivered unfastened), one knock-out opening ring-
flange cover. motor output /
AC-23A
230V 400V 500V 690V
[kW] [kW] [kW] [kW]
Number Number
C-flange cover
entries flanges
bottom side [pcs]
[pcs]
Auxiliary
contacts
included
Auxiliary
contacts
max.
The ordering information for ring-flanges page 46.
Type Ordering number Weight
[kg]
30 2no+2nc 2no+2nc OT90AAUC6AZ 1SCA022542R1920 22
37 2no+2nc 2no+2nc OT125EAUC6AZ 1SCA022542R6050 22
45 2no+2nc 2no+2nc 0T160EAUC6AZ 1SCA022542R6130 32
55 110 132 160 4no+2nc 4no+2nc OT200KAUC6AZ 1SCA022542R6210 39
75 132 160 200 4no+2nc 4no+2nc OT250KAUC6AZ 1SCA022542R6300 45
90 160 200 250 4no+2nc 4no+2nc OT315KAUC6AZ 1SCA022542R6480 45
110 220 280 355 4no+2nc 4no+2nc OT400DAUC6AZ 1SCA022542R6560 48
180 355 400 560 4no+2nc 4no+2nc OT630KAUC6AZ 1SCA022542R6640 85
1no 1nc =
13
14
32
1SCC340006C0201
ABB
..
7 Hr*
Max.
Max. motor output Number Size number Auxiliary Auxiliary Type Ordering number Weight
AC-23A ring-flange
entries on
of ring-flange
covers with
contacts
included
contacts
max.
- C-flanges, the following table illustrates the number C-flange entries bottom Depending the
num ber cables, cover flanges can replaced C-flanges required.
To ordered separately:
- ring-flanges, the following table illustrates the num ber ring-flange entries bottom Depending on
the number cables, ring-flange covers can replaced ring-flanges required. The number ring-flange covers and the size knock-out openings the table below