ABB Jednotka řízení záskoku Návod k instalaci a provozu (4)

| Kategorie: Návody k obsluze Montážní návody  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 79 z 185

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
§ presente schema rappresenta Ínterruttori esecuzione estraibile valido anche per Ínterruttori esecuzione fissa: circuiti ausiliari degli ínterruttori non attestano □I connettore alia morsettiera XV; collegare inoltre morsetto con il morsetto con del dispositivo AT5010. CAPTION A Device type AT5010 for the automatic transfer switch two breakers F1 Fuse with delayed trip K1 Auxiliary contactor for the emergency supplyvoltage presence K2 Auxiliary contactor for the normal supply voltagepresence K51/Q1 Overcurrent relay for emergency supply line * K51/Q2 Overcurrent relay for normal supply line * KC1-KC2 Auxiliary contactors for breakers closing K 01-K Auxiliary contactors for breakers opening M Motor for the closing springs charging Q/1 breaker auxiliary contact Q1 breaker for emergency supply line Q2 breaker for normal supply line Q Miniature breakers for auxiliary circuitsprotection @ 511. ABBSACE ABB ATS010 EMAX RM0020. @ The diagram indicates four-pholes breakers but may applied also two-pholes c.516 Contatti segnalazíone per gli ingressí del dispositivo ATS010 S33M/1 Contatto fine corso delle molle chiusura S51 Contatto per segnalazíone elettrica ¡nterruttore aperto per intervento del relé di massima corrente * S75I/1 Contatto per segnalazíone elettrica interruttore esecuzione estraibile inserito § TI/..001 L2449 /7 . Current transformers feeding the overcurrent relay X Connector for the auxiliary circuits breaker withdrawable version XF Terminal board for the position contacts thewithdrawablec. @ presente schema rappresenta Ínterruttori tetrapolari valido anche per Ínterruttori bipolari: per collegamenti voltmetríci dell’alimentazione nórmale dispositivo AT5010 usare soltanto morsetti (fase neutro); utilizzare inoltre ¡nterruttore ausílíarío di protezione 61/2 bipolare anziché tetrapolare.. Trasformatori corrente per l’alimentazíone del relé massima corrente X Connettore per circuiti ausiliari dell’interruttore esecuzione estraibile XF Morsettiera consegna per contatti posízione dell'interruttore esecuzione estraibile XV Morsettiera consegna per circuiti ausiliari dell’interruttore esecuzione fissa YC Sganciatore chiusura YO Saanciatore apertura NOTA A) Per circuiti ausiliari degli interruttori vedere schema disegno 401587.. + The diagram indicates breakers equipped with overcurrent relay but may applied also breakers without overcurrent relay (switch-disconnectors): connect terminal with one and connect terminal with one ATSD10 device. § The diagram indicates breakers withdrawable version but may applied also to c.. applicazioni indícate dalle seguenti figure sono obbligatorie: fornito relé di massima corrente)-21-31 (solo per interruttori esecuzione estraibile).516 Contacts for the AT5010 device inputs S33M/1 Limit switch the closing springs 551 Contact signalling breaker tripped through the overcurrent relay * S75I/1 Contact signalling breaker withdrawable version connected § Tl/.breaker infixed version YC Shunt closing release YO Shunt opening release NOTE A) For the breakers auxiliary circuits see 401587 diagram.. REPRESENTED OPERATIONAL STATE The diagram represents the following conditions: - breakers open and connected jf - circuits de-energised - closing springs discharged - overcurrent relays not tripped * - AT5010 not powered - generator automatic mode, not started - transfer switch enabled - generator not alarm - logic enabling command (terminal 47). breakers: for normal supply voltmetric connection ATSD10 device, use and terminals only (phase and neutral); furthermore use two-pholes 61/2 auxiliary breaker instead of four-pholes one.. breakers fixed version: breaker auxiliary circuits are not connected connector but the terminal board; furthermore connect terminal with one and connect 35 terminal with one ATS010 device.STATO FUNZIONAMENTO RAPPRESENTATQ Lo schema roppresentaio nelle seguenti condizlonl: - interruttori aperti ínserUi £ - generatore non aliarme - molle chiusura scariche - relé masslma corrente non intervenuti * - AT5010 non aliméntate - generatore funzionamento automático non avviato - commutazione gruppo abilitata - circuitl assenza tensione - lógica abilitata tramite apposito ingresso (morsetto 47). The accessories shown following figures are mandatory: 1—2—4 (if overcurrent relay supplied only)—21 -31 (for breakers in withdrawable version only). LEGENDA A Dispositivo ATS010 per commutazione automatica due ínterruttori F1 Fusibile intervento ritardato K1 Contattore ausílíarío per presenza tensione alimentazione d'emergenza K2 Contattore ausílíarío per presenza tensione alimentazione nórmale K51/Q1 Relé massima corrente della linea alimentazione d'emergenza * K51 Relé massima corrente della linea alimentazione nórmale * KC1-KC2 Contattori ausiliari per chiusura degli Ínterruttori K 01-K Contattori ausiliari per l'apertura degli Ínterruttori M Motore per carica delle molle chiusura Q/1 Contatto ausiliario dell'interruttore Q1 Interruttore della línea alimentazione d’emergenza Q2 Interruttore della línea alimentazione nórmale Q Interruttori termomagnetici per sezionamento protezione dei circuitiausiliari @ S11. + presente schema rappresenta Ínterruttori con relé massima corrente valido anche per Ínterruttori senza relé massima corrente: collegare morsetto con ed il morsetto con del dispositivo ATS010.. breaker XV Terminal board for the auxiliary circuits c