Lightning protection guide by OBO

| Kategorie: Katalog  |

Last revision 2020

Vydal: OBO BETTERMANN s. r. o. Autor: OBO BETTERMANN

Strana 157 z 288

Jak získat tento dokument?






Poznámky redaktora
g.g. This the case when using: • Water-impervious concrete according DIN EN 206 and DIN 1045-2 (white trough) • Bitumen seals (black trough), e.g. 1.TBS Blitzschutz-Leitfaden 2018 / en / 2020/01/10 14:42:40 14:42:40 (LLExport_02613) / 2020/01/10 14:42:54 14:42:54 Earth rods (optional) Ring earth electrodes Main earthing busbar(MEB) Installation principle, foundation earther with functional equipotential bonding cable In order achieve clean insertion, the use strip holders recommended for the installation founda- tion earth electrodes. m. In accordance with DIN 18014, connect the founda- tion earthers each individual foundation the low- est storey into closed ring. This grid ring earther must connected with the functional equipotential bonding conductor and must be executed follows either outside within the floor plate: • Grid width with lightning protection measures • Grid width without lightning protection measures Materials for foundation earthers and functional equipotential bonding conductors The following materials can used, amongst others: • Galvanised steel flat conductors, 3. The connection lugs should clearly marked with protective caps during the construction phase, e.4. necessary, insert trans- verse conductors, order create grid x 20 the earth electrodes not have the neces- sary contact with the earth electrodes the founda- tion, then grid ring earther should additionally in- stalled. made re- cycling crushed glass For further information, see Chapter 2. with the OBO Protec- tionBall.5 mm • Stainless steel flat conductors, 3.4404 1.4571. Materials for ring earthers The following materials can used for the grid ring earther: • Stainless steel flat conductors, 3.4.4. The holders must inserted at a distance approx.5 mm • Copper cable, mm2 • Round conductors made galvanised steel, Ø 10 mm • Round conductors made stainless steel, Ø 10 mm Connection lugs Connection lugs must made materials with per- manent corrosion protection.g. 5018 for marking earthing lugs TBS Blitzschutz-Leitfaden 2018 / en / 2020/01/10 14:42:40 14:42:40 (LLExport_02613) / 2020/01/10 14:42:54 14:42:54 157 Chapter The external lightning protection system . Either hot galvanised steels with plastic jacketing rustproof stainless steels with molybdenum content must be used, e.5 mm • Round conductors made stainless steel, Ø 10 mm • Copper cable, mm² OBO ProtectionBall (item no. bitumen lines • Polymer-modified bitumen thick coating • Impact-resistant plastic webs • Heat insulation (perimeter insulation) the under- side and side walls the foundations • Additionally attached, capillary breaking, poorly electrically conductive earth strata, e. The foundation earth electrodes becomes a functional equipotential bonding conductor