2. the connector has a protective contact (PE), should counted separately. DIN 43652 specifies the design and number contacts for only four types of connectors. 2.1.2: Han® 3A (108 contacts contact) (108 contacts contact) 2.Criteria for Selecting Connectors 23 2 Criteria for Selecting Connectors 2. .1 Electrical Criteria 2. For all other (not standardized) rectangular connectors, the number poles can chosen freely. Examples Fig.1 Number Contacts The pole number (number contacts) important consideration when selecting connector for certain application. Also, certain arrangements have become common.2 Current The rated current (current-carrying capacity) another selection criterion.1. Usually, you must take into account that only useful contacts are counted.1: Han® 108 Fig. The assumed conductor cross-sections can found the derating diagram (power loss curve). The manufacturer’s specification relates the current, which all connector contacts can carry simultaneously