Frekvenční měniče Katalogy, manuály (EN+CZ)

| Kategorie: Katalog  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 58 z 825







Poznámky redaktora
6 0-1 04-0030-5 R4i 30 0.3 0-1 04-0016-5 R3i 15 0.4 0.5 0.3 0-1 04-0011-5 R2i 11 7.7 3.5 0-1 04-0210-5 R8i 200 315 457 200 302 132 236 3.8 0-1 04-0040-5 R4i 37 1.3 0-1 04-0260-5 R8i 250 365 530 250 350 160 273 3.2 0-1 04-0009-5 R2i 7.7 0-1 04-0400-5 R8i 355 525 762 355 504 250 393 5.5 0. The rated current the S800 must higher than equal the rated motor current achieve the rated motor power given the table.5 9.8 0-1 04-0120-5 R7i 110 164 270 110 157 135 2.3.0 0-1 04-0050-5 R5i 45 112 1.max: rated current available continuously without overloadability 40°C. Nominal Ratings: Icont.2 4. ACS800 X04 0003 XXXX No-overload use Nominal ratings Light-overload use Heavy-duty use Heat dissipation kW M odule type Frame size Pcont. Typical Ratings: No-overload use Pcont.1 0-1 04-0140-5 R7i 160 250 363 160 240 110 187 2.2 0-1 04-0006-5 R2i 5. PN: typical motor power light-overload use.5 0.5 0-1 04-0100-5 R6i 90 135 224 130 112 1. 20 3AFE 68248531 REV 31. In lower temperatures the ratings are higher (except Imax). Type Height Width Depth mm mm RDCU control unit 282 126 41 *) Delivered with every unit.0 5.9 2.5 5.0 0-1 04-1820-5 8 R X 3 i 2000 2688 3901 1800 2580 1400 2011 28.0 5.7 0-1 04-0460-5 R8i 500 700 1016 450 672 355 524 7.max kW Icontmax A A Pn kW In A Phd kW Ihd A UN 500 (Range V) 2.2 4.6 2.2004 .5 4.9 0-1 04-2430-5 4xR8 i Dimensions: Frame size Height Width Depth Weight Noise level Air flow mm dB(A) m3/h R2i 401 165 1933) 35 R3i 466 173 2323) 69 R4i 525 240 2523) 103 R5i 673 265 2763) 168 R6i1) 744 228 367 480 R7i1) 744 228 367 480 R8i 1397 235 596 150 1280 2xR8i 1397 2452) 596 300 2560 3xR8i 1397 2452) 596 450 3840 4xR8i 1397 2452) 596 600 5120 1) Dimensions not include cooling fan.5 7.5 0-1 04-0025-5 R3i 22 18.5 3.6 0.max: typical motor power no-overload use.2 4.5 5.5 0.2 0. Phd: typical motor power heavy-duty use.4 0-1 04-0020-5 R3i 19 18.3 0-1 04-0910-5 2xR8 i 900 1372 1991 900 1317 710 1026 14.2 3. Light-overload use In: continuous current allowing 110% for 1min/ min 40°C.0 7. 2) Single module only. H eavy-duty use Ihd: continuous current allowing 150% Ihd for 1min/ min 40°C.5 1.2 0-1 04-0060-5 R5i 55 138 1.7 0-1 04-0610-5 R8i 710 1050 1524 710 1008 500 785 11. Imax: maximum output current. 3) The depth without without control panels and options. The current ratings are the same regardless the supply voltage within one voltage range.1 0-1 04-0004-5 R2i 3 6. The ratings apply 40°C ambient temperature.9 0-1 04-0320-5 R8i 315 455 660 315 437 200 340 4.2 0. Available for start, otherwise long as allowed drive temperature.4 0-1 04-0070-5 R5i 75 112 168 108 1.1 0-1 04-0005-5 R2i 4 8.9 0-1 04-1210-5 8 R X 2 i 1400 2037 2956 1400 1956 1120 1524 22.Multidrive modules ratings, types and voltages Drive module, UN= 500 .1 4.0 7