Technical data KNX medium: TP1-256 Connections - - KNX higher-level line: Connection and junction terminal - - KNX lower-level line: Connection and junction terminal Dimensions - - Modular widths (MW): 2 Notes - - separate power supply required for each line (area line, main line, line) each line segment. three line amplifiers per line connected parallel per line) with devices each possible. Technical data Primary rated voltage: 230 Hz Secondary rated voltage: SELV Secondary rated current: 640 mA, short-circuit-proof Zero-voltage 2-way switch: 230 6A Connections - - KNX: Connection and junction terminal - - Load: Screw terminals - - max. - - Support the completely expanded group address area from 0 to with the functions "block", "forward unfiltered", and "filter" in both communication directions between the main and subline. - - The uninterruptible power supply has zero-voltage 2-way switch for reporting fault (e. - - Recommendation: Overvoltage protection for Gira KNX products.set 1128 D538 COptional accessories Extension cab. - - Reduction the bus load via filter function (filter table). mains failure, battery failure, overload, or short circuit).g. Scope supply - - KNX connection and junction terminal included the scope of supply. System devices KNX power supply 640 uninterruptible KNX area/line coupler line amplifier . - - Overvoltage diverter BUStector 24, manufacturer: DEHN + SÖHNE, Article No. Area/line coupler - - Use area line coupler, depending the specification of the physical address and parameterisation. - - With connections for lead-gel rechargeable accumulators for buffering KNX voltage case mains failure. unit Specifications Order No. - - Repetition rate the case transfer errors. DRA plus 102300 1023 1/100 66 Features - - The area/line coupler connects two KNX lines each other for data transfer and ensures electrical isolation between these lines. As result, each bus line KNX installation can operated electrically independently the other lines.set 1129 D538 Features - - The uninterruptible power supply 640 generates the KNX system voltage. 925001. unit PS Price system (PS) 14: reduced discount Gira electrical installation systems KNX system devices, actuators, sensors DRA 107900 1079 1/100 26 CNecessary accessories Rech. mm² Dimensions - - Modular widths (MW): 8 Notes - - Connection made via KNX bus connection junction terminals (no data rail required). - - Repetition rate the case transfer errors. - - Telegram confirmation the main and subline possible separately for group telegrams and physically addressed telegrams with the settings "always" and "for forwarding only". Line amplifier - - line amplifier, extending the lines max.513 System devices KNX Specifications Order No. - - "Forward unfiltered" and "block" functions can also selected for physically addressed telegrams between main and subline in both communication directions (programming and tamper protection). four line segments (max.lead acid bat. - - For physically addressed telegrams, the setting "always reject NACK (Not-Acknowledge)" can selected (programming protection with feedback). - - two lead-gel rechargeable accumulators can connected and charged via the uninterruptible power supply. - - "Repeat: yes/no" function can set separately case transfer errors the main subline for the telegram type "Broadcast". - - Forwarding group telegrams can parameterised. - - Telegram confirmation can parameterised. - - The charging voltage controlled depending the temperature using temperature sensor. 1130 D538 Basic cab. - - With integrated choke for de-coupling the bus line from the power supply