ABB Vzduchové jističe EMAX E1-E6 Montážní návody a manuály (03)

| Kategorie: Návody k obsluze Montážní návody  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 422 z 660

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
Some examples possible constructions relation the shape and size the circuit-breaker terminals are given this paragraph.5. 17 FRONT FLAT Model 2234 Apparatus Scale L 2778 Doc-No' 1SDH000460R0002 Page No.1. V rtic riz and fro ls C ircuit-breaker [A] Continuous current- Busbar cross-section Continuous current- Busbarcross-section 3 Cn C carrying capacity [A] 45 °C [m 2] carrying capacity [A] 35 °C [m 2] E1B/N 800 800 800 800 1x(60x10) 800 800 800 1x(60x10) E1B/N 1000 1000 1000 1000 1x(80x10) 1000 1000 1000 2x(60x8) E1B/N 1250 1250 1250 1250 1x(80x10) 1250 1250 1200 2x(60x8) E1B/N 1600 1600 1600 1500 2x(60x10) 1550 1450 1350 2x(60x10) E2S 800 800 800 800 1x(60x10) 800 800 800 1x(60x10) E2N/S 1000 1000 1000 1000 1x(60x10) 1000 1000 1000 1x(60x10) E2N/S 1250 1250 1250 1250 1x(60x10) 1250 1250 1250 1x(60x10) E2B/N/S 1600 1600 1600 1600 2x(60x10) 1600 1600 1530 2x(60x10) E2B/N/S 2000 2000 2000 1800 3x(60x10) 2000 2000 1750 3x(60x10) E2L 1250 1250 1250 1250 1x(60x10) 1250 1250 1250 1x(60x10) E2L 1600 1600 1600 1500 2x(60x10) 1600 1500 1400 2x(60x10) E3H/V 800 800 800 800 1x(60x10) 800 800 800 1x(60x10) E3S/H 1000 1000 1000 1000 1x(60x10) 1000 1000 1000 1x(60x10) E3S/H/V 1250 1250 1250 1250 1x(60x10) 1250 1250 1250 1x(60x10) E3S/H/V 1600 1600 1600 1600 1x(100x10) 1600 1600 1600 1x(100x10) E3S/H/V 2000 2000 2000 2000 2x(100x10) 2000 2000 2000 2x(100x10) E3N/S/H/V 2500 2500 2500 2500 2x(100x10) 2500 2450 2400 2x(100x10) E3N/S/H/V 3200 3200 3100 2800 3x(100x10) 3000 2880 2650 3x(100x10) E3L 2000 2000 2000 2000 2x(100x10) 2000 2000 1970 2x(100x10) E3L 2500 2500 2390 2250 2x(100x10) 2375 2270 2100 2x(100x10) E4H/V 3200 3200 3200 3200 3x(100x10) 3200 3150 3000 3x(100x10) E4S/H/V 4000 4000 3980 3500 4x(100x10) 3600 3510 3150 6x(60x10) E6V 3200 3200 3200 3200 3x(100x10) 3200 3200 3200 3x(100x10) E6H/V 4000 4000 4000 4000 4x(100x10) 4000 4000 4000 4x(100x10) E6H/V 5000 5000 4850 4600 6x(100x10) 4850 4510 4250 6x(100x10) E6H/V 6300 6000 5700 5250 7x(100x10) - Fig.2 Examples positioning the connection busbars according the types terminals The connection busbars enable the connection between the terminals the circuit-breakers and the busbars the switchgear. The various types ofterminals are constant dimensions for each size circuit-breaker: normally advisable to exploit the whole contact surface the terminal, the width the connection busbars should the same that the terminal. some cases, reductions the width of the connection relation that the terminal are allowable shown the following examples. Different connection capacities can obtained adjusting the thickness and number busbars parallel. ------------------------------------------------------------------------------------------------------------------------------------------ P ositioning the first anchoring baffle the busbars according the rt-circuit current Anchoring the switchgear HORIZONTAL VERTICAL p + + P E1-E2 E3-E4-E6 E1-E6 HORIZONTAL 250 150 - VERTICAL 250 150 - FRONT 250 FLAT 250 Fig. 11/158 . Their sizing must be carefully studied the switchgear designer