] basic curve (see figure 4.197), shall specified the relevant detail specification. recommended that the method described this standard used accordingly these cases. For these cases, general rules cannot established and the limits must determined for each individual case. NOTE: practice, usually the case that all terminals are not loaded simultaneously with the maximum permissible current. 4.g.198: Example current-carrying capacity graph The derating factor justified because the current-carrying capacity may be limited further external factors, e. the size the wire and unequal distribution the loaded circuits. In many cases, the individual terminals can carry several times the derated current indicated the derating curve when less than % of the total complement used. This curve takes into account variations specimens as well errors temperature measurements the measuring equipment.Corrected current-carrying capacity curve (derating curve) A corrected current-carrying capacity curve (derating curve), derived from the [. . 158 ____________________________________________________________ 0 fu3 <u2 tu\ Ambient temperature Fig.. these factors result current- carrying capacity other than that which may expected due thermal limitations, then revised value shall apply.