. Due the hexagonal slot, each module can be
used different positions (turning every degrees).
4. Strip the conductor length 19+1 mm
2.
Therefore important that the corresponding modules are assembled
in the correct position mating not possible.2. Push the conductor through the cable gland and the housing. the
same time, push the conductor over the axial screw. After the assembly the modules the housing, the tightning torque of
the locking screw can checked and corrected necessary.
Insert the hexagonal wrench the mating side the contact.43 44: Mounting instructions
1.
5. The modules have hexagonal around which mates with the
metal frame.
The user should make sure that the cable adequately strain reliefed to
protect the contact from radial stress.
3. The heads the fixing screws have face the mating
direction the module. Once all modules are terminated, they are mounted into the housing by
means two metal frames (tightning torque the fixing screws 0. Insert the
stripped end the conductor into the termination entry the module
until the insulation touches the contact.5
Nm). The locking screw
has tightened with the recommended tightning torque that is
determined the conductor's cross section (6-14 Nm).3 Assembly manual for Han®HC Modular 350 A
Fig.Special Applications 195
5.3. 5. This possibility
can used create coding system. tighten the locking screw, hexagonal wrench size needed. Final assembly the contacts.
6